• Anesthesia and analgesia · Oct 2014

    Observational Study

    Trending and Accuracy of Noninvasive Hemoglobin Monitoring in Pediatric Perioperative Patients.

    • Mario Patino, Lindsay Schultz, Monir Hossain, Jennifer Moeller, Mohamed Mahmoud, Joel Gunter, and C Dean Kurth.
    • From the Department of Anesthesiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
    • Anesth. Analg.. 2014 Oct 1;119(4):920-5.

    BackgroundRainbow Pulse CO-Oximetry technology (Masimo Corporation, Irvine, CA) provides continuous and noninvasive measurement of arterial hemoglobin concentration (SpHb). We assessed the trending and accuracy of SpHb by this innovative monitoring compared with Hb concentration obtained with conventional laboratory techniques (Hb) in children undergoing surgical procedures with potential for substantial blood loss.MethodsHb concentrations were recorded from Pulse CO-Oximetry and a conventional hematology analyzer. Regression analysis and 4-quadrant plot were used to evaluate the trending for changes in SpHb and Hb measurements (ΔSpHb and ΔHb). Bias, precision, and limits of agreement of SpHb and of in vivo adjusted SpHb (SpHb - first bias to HB) compared with Hb were calculated.ResultsOne hundred fifty-eight SpHb-Hb data pairs and 105 delta pairs (ΔSpHb and ΔHb) from 46 patients aged 2 months to 17 years with Hb ranging from 16.7 to 7.9 g/dL were collected. To evaluate trending, the delta pairs (ΔSpHb and ΔHb) were plotted, which revealed a positive correlation (ΔSpHb = 0.022 + 0.76ΔHb) with correlation coefficient r = 0.76, 95% CI [confidence interval] = 0.57-0.86. The bias and precision of SpHb to Hb and in vivo adjusted SpHb were 0.4 ± 1.3 g/dL and 0.1 ± 1.2 g/dL, respectively; the limits of agreement were -2.0 to 3.2 g/dL before in vivo adjustment and -2.4 to 2.2 g/dL after in vivo adjustment (P value = 0.04). The mean percent bias (from the reference Hb concentration) decreased from 4.1% ± 11.9% to 0.7% ± 11.3% (P value = 0.01). No drift in bias over time was observed during the study procedure. Of patient demographic and physiological factors tested for correlation with the SpHb, only perfusion index at sensor site showed a weak correlation.ConclusionsThe accuracy of SpHb in children with normal Hb and mild anemia is similar to that previously reported in adults and is independent of patient demographic and physiological states except for a weak correlation with perfusion index. The trending of SpHb and Hb in children with normal Hb and mild anemia showed a positive correlation. Further studies are necessary in children with moderate and severe anemia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.