• Surg Radiol Anat · Apr 2012

    A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis.

    • Mun Keong Kwan, Amit Jeffry, Chris Yin Wei Chan, and Lim Beng Saw.
    • Department of Orthopedic Surgery, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia. munkeong42@hotmail.com
    • Surg Radiol Anat. 2012 Apr 1;34(3):217-27.

    IntroductionStudies of sacral pedicle anatomy have been reported in the European population. However, the feasibility for the use of S1, S2 and S2-ilium screws has not been fully investigated in the Asian population.PurposeTo assess feasibility, morphometric parameters and safety of S1, S2 and S2-ilium screw insertion in the Asian population.Method180 three dimensional computed tomography (CT) scans of pelvis (90 males and 90 females) with contrast were analysed using Mimics(®) version 13.1 (Materialise, Belgium) software. All parameters were measured using this programme.ResultThe safety medial trajectory of S1 pedicle screw was 11.8 ± 3.9 to 37.1 ± 4.5° in males and 11.7 ± 3.1 to 35.9 ± 4.4° in females. The screw length was from 35.0 ± 3.0 to 58.3 ± 3.1 mm in males and from 31.9 ± 2.6 to 53.1 ± 3.5 mm in females. Right S1 pedicle screws were safe as long as the anterior cortical penetration of quadrant 2, 3 and 4 were avoided. On the left, it was safe for the screws to exit at quadrant 1, 2 and 3. The lateral trajectory of S2 sacral alar screw was from 0 to 32.6 ± 3.3° in males and from 0 to 33.6 ± 3.5° in females. The screw length was from 23.9 ± 3.2 to 53.1 ± 4.1 mm in males and from 23.0 ± 2.5 to 53.2 ± 4.5 mm in females. For S2 screws, on the right side, the frequency of the internal iliac artery location was 7.2, 38.3, 47.2 and 1.7% for quadrants 1, 2, 3 and 4, whereas on the left side, the frequency was 7.8, 50.6, 33.9 and 2.2% for quadrants 1, 2, 3 and 4. For S2-ilium screws, the lateral trajectory was from 39.3 ± 3.1 to 50.4 ± 6.1° in males and from 39.5 ± 3.1 to 50.2 ± 5.9° in females. The screw lengths were from 85.3 ± 22.2 to 122.6 ± 11.4 mm and from 86.4 ± 22.7 to 122.2 ± 11.9 mm in males and females, respectively.ConclusionThe application of S1, S2 and S2-ilium screws are feasible. The amount of medial angulation and the ideal screw length in the Asian population must be borne in mind during insertion. Right S1 screws carry higher risk of injury to the internal iliac artery when the anterior cortical penetration occurs due to the course of the iliac vessels.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…