• Paediatric anaesthesia · Oct 2014

    Randomized Controlled Trial Comparative Study

    The randomized crossover comparison of airway sealing with the laryngeal mask airway Supreme(™) at three different intracuff pressures in children.

    • Kwan-Woong Choi, Jeong-Rim Lee, Jung-Tak Oh, Dong Wook Kim, and Min-Soo Kim.
    • Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
    • Paediatr Anaesth. 2014 Oct 1; 24 (10): 1080-7.

    BackgroundAn intracuff pressure of 80 cm H2 O in the adult-sized laryngeal mask airway Supreme has been recommended to obtain a higher oropharyngeal leak pressure (OLP). However, the intracuff pressure for the higher OLP in the pediatric laryngeal mask airway Supreme could be different from that in the adult-sized laryngeal mask airway Supreme. Thus, we measured and compared OLP at three intracuff pressures of 40, 60, and 80 cm H2 O in the pediatric laryngeal mask airway Supreme.MethodsThis study was designed as a randomized crossover study and enrolled 36 children, aged 0-108 months and 5-30 kg in weight. After insertion of the laryngeal mask airway Supreme, oropharyngeal leak pressure (OLP) was measured at intracuff pressures of 40, 60, and 80 cm H2 O according to one of six sequences produced on the basis of 3 × 6 Williams crossover design. During the intraoperative period, the laryngeal mask airway Supreme was maintained using the last intracuff pressure of the allocated sequence. The intraoperative and postoperative complications were compared among three maintenance intracuff pressures.ResultsOLP at the intracuff pressure of 60 cm H2 O was significantly higher than that of 40 cm H2 O (17.9 ± 3.9 vs 16.9 ± 4.2 cm H2 O, P = 0.004) and was comparable with that of 80 cm H2 O (17.9 ± 3.9 vs 17.8 ± 4.6 cm H2 O, P = 0.938). There were no significant differences of intraoperative and postoperative complications among the three maintenance intracuff pressures.ConclusionOur results suggest that the use of an intracuff pressure of 60 cm H2 O in pediatric laryngeal mask airway Supreme provides a higher OLP compared with 40 cm H2 O.© 2014 John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…