Anesthesia and analgesia · Jul 2002
Comparative Study Clinical TrialRepeated deflation of a gas-barrier cuff to stabilize cuff pressure during nitrous oxide anesthesia.
- Fujio Karasawa, Nobuhiro Matsuoka, Mitsuyoshi Kodama, Tomohiro Okuda, Tomohisa Mori, and Yasushi Kawatani.
- Department of Anesthesiology, National Defense Medical College, Tokorozawa, Saitama 359-8513, Japan. karasawa@me.ndmc.ac.jp
- Anesth. Analg. 2002 Jul 1;95(1):243-8, table of contents.
UnlabelledAlthough a nitrous oxide (N(2)O) gas-barrier cuff effectively limits the increase of cuff pressure during N(2)O anesthesia, there are few data assessing whether an N(2)O gas-barrier cuff is more beneficial for stabilizing intracuff pressure than standard endotracheal tubes when cuffs are repeatedly deflated to stabilize pressure during N(2)O anesthesia. In the present study, the pressure of air-filled standard-type cuffs (Trachelon; Terumo, Tokyo, Japan) and N(2)O gas-barrier type endotracheal tube cuffs (Profile Soft-Seal Cuff [PSSC]; Sims Portex, Kent, UK) was measured during 67% N(2)O anesthesia (n = 8 in each), during which the cuffs were repeatedly deflated every 30 min (Trachelon) or 60 min (PSSC) for the first 3 or 4 h. After aspirating the cuffs for 3 h, the cuff pressure exceeded 22 mm Hg in more than half of the patients in both groups. However, aspiration of the cuffs for 4 h decreased the maximal cuff pressure between deflation intervals in both groups (P < 0.01 for each), and increased the intracuff N(2)O concentration (P < 0.0001 for each). After deflating the cuffs over 4 h, the cuff pressure in both groups never exceeded 22 mm Hg during the subsequent 3 h, and intracuff N(2)O concentrations did not significantly change. Therefore, deflation of cuffs for 4 h during N(2)O anesthesia sufficiently stabilized cuff pressure and equilibrated the intracuff N(2)O concentrations in both groups. The use of the PSSC endotracheal tube might be more practical because of the smaller number of cuff deflations required, but the PSSC does not reduce the duration of cuff deflations to stabilize the pressure.ImplicationsWe demonstrated that the N(2)O concentration and pressure in the N(2)O-barrier Profile Soft-Seal Cuff stabilized when the cuff was aspirated once an hour for 4 h during N(2)O anesthesia. The Profile Soft-Seal Cuff might be easier to use in clinical practice than standard endotracheal tubes because of the smaller number of cuff deflations required.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.