• Int. J. Cardiol. · Jun 2008

    Letter

    Non-invasive ultrasonic cardiac output monitoring in exercise testing.

    • Karsten Knobloch, Volker Hoeltke, Ernst Jakob, Peter M Vogt, and Rob Phillips.
    • Int. J. Cardiol. 2008 Jun 6;126(3):445-7.

    BackgroundThe purpose of this study was to evaluate the relationship of breath-by-breath oxygen uptake (VO(2)) and CO, cardiac index (CI), stroke volume (SV) and heart rate (HR) determined by a non-invasive continuous wave (CW) Doppler-based system (USCOM) in healthy adolescent and adult athletes during exercise treadmill testing.MethodsTwenty athletes were enrolled for a standardized ramp treadmill test including transthoracic echocardiography at rest, incremental breath-by-breath spiroergometry, lactate kinetics and CW Doppler.ResultsVO(2) max was 51+/-11 ml/min/kg in the adolescent cross country skiers (CI 8.2+/-1.2 l/min/m(2)) and 50+/-12 ml/min/kg in adult soccer referees (CI 7.1+/-1.2 l/min/m(2)). CW Doppler hemodynamic variables showed significant correlation with VO(2) (p<0.01, n=95) across the total of measures, with excellent correlation demonstrated for CO and CI (0.904 and 0.897), while HR and SV showed good to very good correlation with r values of 0.842 and 0.766, respectively. Correlation of the variables at peak exercise and 1 and 3 min after recovery, demonstrate that CO and SV show superior correlation with peak oxygen consumption (VO(2) max). The regression equation for VO(2) and CO(USCOM) was VO(2)=4.43CO(USCOM)-10.3.ConclusionCW Doppler measurement of cardiac output is feasible as a measure of cardiac performance during standardized treadmill testing in adolescent and adult athletes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…