-
Multicenter Study Clinical Trial
Early mobilization on continuous renal replacement therapy is safe and may improve filter life.
- Yi Tian Wang, Terry P Haines, Paul Ritchie, Craig Walker, Teri A Ansell, Danielle T Ryan, Phaik-Sim Lim, Sanjiv Vij, Rebecca Acs, Nigel Fealy, and Elizabeth H Skinner.
- Crit Care. 2014 Jul 28; 18 (4): R161.
IntroductionDespite studies demonstrating benefit, patients with femoral vascular catheters placed for continuous renal replacement therapy are frequently restricted from mobilization. No researchers have reported filter pressures during mobilization, and it is unknown whether mobilization is safe or affects filter lifespan. Our objective in this study was to test the safety and feasibility of mobilization in this population.MethodsA total of 33 patients undergoing continuous renal replacement therapy via femoral, subclavian or internal jugular vascular access catheters at two general medical-surgical intensive care units in Australia were enrolled. Patients underwent one of three levels of mobilization intervention as appropriate: (1) passive bed exercises, (2) sitting on the bed edge or (3) standing and/or marching. Catheter dislodgement, haematoma and bleeding during and following interventions were evaluated. Filter pressure parameters and lifespan (hours), nursing workload and concern were also measured.ResultsNo episodes of filter occlusion or failure occurred during any of the interventions. No adverse events were detected. The intervention filters lasted longer than the nonintervention filters (regression coefficient = 13.8 (robust 95% confidence interval (CI) = 5.0 to 22.6), P = 0.003). In sensitivity analyses, we found that filter life was longer in patients who had more position changes (regression coefficient = 2.0 (robust 95% CI = 0.6 to 3.5), P = 0.007). The nursing workloads between the intervention shift and the following shift were similar.ConclusionsMobilization during renal replacement therapy via a vascular catheter in patients who are critically ill is safe and may increase filter life. These findings have significant implications for the current mobility restrictions imposed on patients with femoral vascular catheters for renal replacement therapy.Trial RegistrationAustralian and New Zealand Clinical Trials Registry ACTRN12611000733976 (registered 13 July 2011).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.