Oral Surg Oral Med O · Nov 1999
Comparative study of different syringes in positive aspiration during inferior alveolar nerve block.
- E Delgado-Molina, S Bueno-Lafuente, L Berini-Aytés, and C Gay-Escoda.
- University of Barcelona, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Spain.
- Oral Surg Oral Med O. 1999 Nov 1;88(5):557-60.
ObjectiveThe purpose of this study was to evaluate the detection of intravascular injection or hematic aspiration in relation to (a) the particular combination of syringe system and needle (there being 3 different syringe systems [2 self-aspirating and 1 non-self-aspirating] and 3 different needles); (b) the anesthetic technique used (direct or indirect) to induce inferior alveolar nerve block; (c) patient sex; and (d) the operator performing the block.Study DesignTwo operators performed 246 inferior alveolar nerve blocks (on 90 male and 156 female patients) using 3 syringe systems (1 non-self-aspirating (Uniject K) and 2 self-aspirating (Aspiject and Inibsaject)) and 3 types of needle in terms of length and gauge combination (30G/25 mm, 27G/25 mm, and 27G/35 mm) for conventional and surgical extractions of lower third molars. Three aspirations were made at each of 3 different times in each block. Hematic aspiration was accepted only if a blood jet rose forcefully along the cartridge on aspiration. In each block, the age and sex of the patient was recorded, along with the latency or time elapsed from introduction of the anesthetic solution to onset of the anesthetic effect, the depth of the needle at contact with the mandibular ramus, and the operator performing the block.ResultsSignificant differences (P <.05) were observed with respect to hematic aspiration and the syringe system used, the Uniject K system yielding higher percentage hematic aspirations (5.69%) than either of the self-aspirating systems, Inibsaject (2.03%) and Aspiject (1. 21%). However, no significant differences (P >.05) were observed with respect to number of aspirations, needle length, needle gauge, anesthetic technique performed, patient's sex, or operator performing the inferior alveolar nerve block. The incidence of hematic aspirations was 8.9%. The mean latency time was 39.03 seconds, and the mean needle depth at contact with the mandibular ramus was 20.72 mm.ConclusionsThe Uniject K non-self-aspirating syringe system was associated with a higher number of hematic aspirations than the self-aspirating systems (Inibsaject and Aspiject). However, the detection of hematic aspirations was not dependent on length or gauge of the needles used, anesthetic technique performed (direct or indirect), patient's sex, or operator who performed the block.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.