Int J Obstet Anesth · Jul 2009
An observational cohort study of the meniscus test to detect intravascular epidural catheters in pregnant women.
- M N Servin, J M Mhyre, M L V H Greenfield, and L S Polley.
- Department of Anesthesiology, Division of Obstetric Anesthesiology, Women's Hospital, University of Michigan Health System, Ann Arbor, Michigan 48109-5278, USA. monicar@med.umich.edu
- Int J Obstet Anesth. 2009 Jul 1;18(3):215-20.
BackgroundThe meniscus test is a rapid non-pharmacologic method of confirming epidural catheter placement by observing a normal saline meniscus while physically manipulating the catheter. The aim of this study was to assess whether the meniscus test improves diagnostic accuracy of aspiration to detect intravascular or intrathecal placement of epidural catheters in pregnant women.MethodsIn this prospective observational study, parturients at >or= 36 weeks of gestation were recruited. In the sitting position, participants received a multiorifice epidural catheter for elective cesarean delivery or labor analgesia. After aspiration was confirmed to be negative for blood and cerebrospinal fluid, the meniscus test was performed. Subsequently, a pharmacologic test dose was given with 1.5% lidocaine 3 mL and epinephrine 15 microg. Intravascular placement was diagnosed if the patient experienced an increase in heart rate >or= 20 beats/min within 2 min with or without tinnitus, metallic taste, dizziness, palpitations, headache, or anxiety.ResultsThe overall intravascular catheter rate was 5.7% (24/419). The rate of intravascular catheter location not detected by aspiration was 0.95% (4/419). Given negative catheter aspiration, the meniscus test demonstrated 25% sensitivity, 87.5% specificity, and 1.9% positive predictive value for intravascular catheter insertion. No intrathecal catheters were observed.ConclusionsFor obstetric patients in the sitting position, the meniscus test does not improve diagnostic accuracy of aspiration for detecting intravascular multiorifice epidural catheter placement.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.