• Neurosurg Focus · Aug 2013

    Minimally invasive transforaminal lumbar interbody fusions and fluoroscopy: a low-dose protocol to minimize ionizing radiation.

    • Justin C Clark, Gary Jasmer, Frederick F Marciano, and Luis M Tumialán.
    • Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ 85013, USA.
    • Neurosurg Focus. 2013 Aug 1;35(2):E8.

    ObjectThere is an increasing awareness of radiation exposure to surgeons and the lifelong implications of such exposure. One of the main criticisms of minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) is the amount of ionizing radiation required to perform the procedure. The goal in this study was to develop a protocol that would minimize the fluoroscopy time and radiation exposure needed to perform an MIS TLIF without compromising visualization of the anatomy or efficiency of the procedure.MethodsA retrospective review of a prospectively collected database was performed to review the development of a low-dose protocol for MIS TLIFs in which a combination of low-dose pulsed fluoroscopy and digital spot images was used. Total fluoroscopy time and radiation dose were reviewed for 50 patients who underwent single-level MIS TLIFs.ResultsFifty patients underwent single-level MIS TLIFs, resulting in the placement of 200 pedicle screws and 57 interbody spacers. There were 28 women and 22 men with an average age of 58.3 years (range 32-78 years). The mean body mass index was 26.2 kg/m(2) (range 17.1-37.6 kg/m(2)). Indications for surgery included spondylolisthesis (32 patients), degenerative disc disease with radiculopathy (12 patients), and recurrent disc herniation (6 patients). Operative levels included 7 at L3-4, 40 at L4-5, and 3 at L5-S1. The mean operative time was 177 minutes (range 139-241 minutes). The mean fluoroscopic time was 18.72 seconds (range 7-29 seconds). The mean radiation dose was 0.247 mGy*m(2) (range 0.06046-0.84054 mGy*m(2)). No revision surgery was required for any of the patients in this series.ConclusionsAltering the fluoroscopic technique to low-dose pulse images or digital spot images can dramatically decrease fluoroscopy times and radiation doses in patients undergoing MIS TLIFs, without compromising image quality, accuracy of pedicle screw placement, or efficiency of the procedure.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.