-
Randomized Controlled Trial Comparative Study
Randomized prospective trial comparing two supraglottic airway devices: i-gel™ and LMA-Supreme™ in paralyzed patients.
- Nikola Joly, Louis-Pierre Poulin, Issam Tanoubi, Pierre Drolet, François Donati, and Patrick St-Pierre.
- Département d'anesthésiologie, Centre Hospitalier de l'Université de Montréal (CHUM), Université de Montréal, Pavillon Hôpital Saint-Luc, Montréal, QC, Canada.
- Can J Anaesth. 2014 Sep 1;61(9):794-800.
PurposeMany features can influence the choice of a supraglottic airway device (SAD), including ease of insertion, adequate ventilation pressures and lack of adverse effects. The goal of this randomized prospective trial was to compare the performance of the i-gel™ with that of the LMA-Supreme™.MethodsOne hundred adult patients (American Society of Anesthesiologists I-III) scheduled to undergo elective surgery under general anesthesia were randomized to either an i-gel (n = 50) or an LMA-Supreme (n = 50). The primary objective was to compare ventilation pressures. Secondary objectives included time and number of attempts needed to introduce the device, adverse effects, and repositioning. The endoscopic view of the glottic aperture and the position of the drain tubes in relation to the esophagus were also evaluated.ResultsThe devices were inserted successfully in 46 (92%) patients in both groups. There was no significant difference in the [mean (SD)] leak pressure [i-gel: 23 (7) cm H2O vs LMA-Supreme: 21 (8) cm H2O; P = 0.14] or peak inspiratory pressure between both devices. Insertion time was shorter with the i-gel than with the LMA-Supreme [19 (7) sec vs 27 (17) sec, respectively; P = 0.003]. The vocal cords were completely visualized more often through the i-gel (70%) than through the LMA-Supreme (50%) (P = 0.007). Esophageal mucosa was easily visualized through the drain port in all but four patients, two patients in each group. There was no difference between groups regarding preoperative or postoperative complications. Postoperative patient discomfort was generally mild and comparable between both devices.ConclusionBoth the LMA-Supreme and the i-gel offer similar performance for positive pressure ventilation in paralyzed patients during general anesthesia. The i-gel was associated with a slightly faster insertion time and better fibrescopic visualization of the glottis. This trial was registered at Clinicaltrials.gov: NCT01001078.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.