• Sleep · Jun 1998

    Comparative Study

    Importance of the pulse oximeter averaging time when measuring oxygen desaturation in sleep apnea.

    • R Farré, J M Montserrat, E Ballester, L Hernández, M Rotger, and D Navajas.
    • Lab. Biofísica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Barcelona, Spain.
    • Sleep. 1998 Jun 15;21(4):386-90.

    AbstractThe accuracy of pulse oximeters in measuring transient changes in oxygen saturation (SaO2) may be affected by the oximeter time response. The aim of this study was to assess the effect of modifying the pulse oximeter averaging time (T) on the measurement of SaO2 in patients with the sleep apnea-hypopnea syndrome (SAHS). Twelve patients with severe SAHS were studied during a nap with conventional oximeters: Ohmeda 3740 and Criticare 501. We compared the readings of each patient's oxygen desaturation measured simultaneously with two identical pulse oximeters. One oximeter was the control (T = 3 seconds), and in the other T was set from 3 seconds to 21 seconds. No significant differences in SaO2 were found when both oximeters were set to the same T (3 seconds). In contrast, increasing T to 12 seconds and 21 seconds in one of the oximeters resulted in considerable and significant differences in the measured SaO2: oxygen desaturation was underestimated by up to 60% when compared with the control. The misestimation of SaO2 induced by settings of T which are within the range selectable in conventional oximeters may be of epidemiological significance when pulse oximetry is used as a complementary diagnostic tool to classify sleep events in SAHS.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.