• J Paediatr Child Health · Jan 2014

    Comparative Study

    Dräger VN500's oscillatory performance has a frequency-dependent threshold.

    • Jubal John, Edward R Harcourt, Peter G Davis, and David G Tingay.
    • Neonatal Research, Murdoch Children's Research Institute, Melbourne, Victoria, Australia; Neonatal Research, Royal Women's Hospital, Parkville, Victoria, Australia.
    • J Paediatr Child Health. 2014 Jan 1;50(1):27-31.

    AimThe aim of this study is to compare the high-frequency pressure amplitude (oscillatory change in pressure (ΔP)) and tidal volume (high-frequency tidal volume at the airway opening (VTHF )) delivered by the Dräger VN500 (Drägerwerk Ag & Co., Lübeck, Germany) and the Sensormedics 3100 (SM3100; CareFusion, San Diego, CA, USA) through a range of oscillatory frequencies.MethodsIn this benchtop study, high-frequency oscillations were applied to an infant test lung at unrestricted set amplitudes. Pressure and flow were measured as a function of frequency, incremented by 1 Hz from 5 to 15 Hz. Measurements were repeated for a range of ventilator settings, and lung resistive and compliance states.ResultsThe VN500, but not the SM3100, demonstrated an exponential decrease in airway opening ΔP as frequency increased. The difference between the SM3100- and VN500-delivered VTHF became greater with each frequency increment. At 15 Hz, VN500 VTHF was 49% of SM3100 VTHF .ConclusionsThe VN500 demonstrates a frequency-related reduction in ΔP not observed in the SM3100. Clinicians need to be aware of these differences in performance characteristics.© 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…