• Resuscitation · Nov 2014

    Accurate Feedback of Chest Compression Depth on a Manikin on a Soft Surface with Correction for Total Body Displacement.

    • Stefanie G Beesems and Rudolph W Koster.
    • Academic Medical Center, Department of Cardiology, Amsterdam, The Netherlands. Electronic address: s.g.beesems@amc.nl.
    • Resuscitation. 2014 Nov 1;85(11):1439-43.

    ObjectiveTrueCPR is a new real-time compression depth feedback device that measures changes in magnetic field strength between a back pad and a chest pad. We determined its accuracy with a manikin on a test bench and on various surfaces.MethodsFirst, calibration and accuracy of the manikin and TrueCPR was verified on a drill press. Then, manual chest compressions were given, on a firm surface and on a foam or air mattress, with feedback of the TrueCPR or Q-CPR accelerometer, to achieve a depth of 50mm. Compression depth measurements by the devices and the manikin were compared.ResultsOn a hard surface TrueCPR showed a systematic underestimation of 2-3mm in the drill press. Manual tests on a hard surface showed a slightly larger underestimation of 4.5mm. When guided by TrueCPR on a foam or air mattress, the TrueCPR measured a mean(±SD) chest compression depth of 52.0(±1.9)mm and 49.4(±2.6)mm respectively, while the manikin measured 54.4(±1.8)mm and 52.1(±1.4)mm, respectively (p<0.001). When guided by the Q-CPR accelerometer on a foam or air mattress, the accelerometer measured depth of 54.3(±3.6)mm and 56.0(±3.8)mm respectively, compared to the manikin 42.4(±2.3)mm and 34.9(±3.6)mm, respectively (p<0.001).ConclusionTrueCPR measures depth precisely, independent of the stiffness of the surface upon which the CPR is being performed with a constant inaccuracy of <4.5mm. A sternum-only accelerometer substantially overestimates depth when performing CPR on a soft surface. Correction for body displacement on a soft surface is essential for accurate delivery of chest compressions within the recommended depth range.Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.