-
Multicenter Study Comparative Study
Correlation of intracardiac electrogram with surface electrocardiogram in Brugada syndrome patients.
- Vincent Probst, Frederic Sacher, Nicolas Derval, Jean Baptiste Gourraud, Philippe Mabo, Fariza Medkour, Hervé Le Marec, and John Gill.
- l'institut du thorax, Cardiology Department, Nantes University Hospital, service de cardiologie, CHU de Nantes, 44000 Nantes, France INSERM U1087, l'institut du thorax, Nantes, France vincent.probst@chu-nantes.fr.
- Europace. 2014 Jun 1;16(6):908-13.
AimsThe objective of this study was to correlate the electrocardiogram (ECG) modification during an Ajmaline challenge in patients affected by the Brugada syndrome and implanted with an implantable cardioverter-defibrillator (ICD) with the morphological changes of their ICD's intracardiac electrogram (IEGM).Methods And ResultsSixteen type 1 Brugada syndrome patients implanted with a St Jude Medical AnalyST(®) ICD were enrolled and underwent ajmaline challenge. Intracardiac electrograms and 12 lead ECG signals were collected over the duration of the study and analysed off-line. The right precordial ECG leads were in both the third and fourth intercostal space by putting V5 and V6 in V1 and V2 at the third intercostal space. Two patients were excluded from the analysis due to signal noise issues. Of the remaining 14 patients, 12 and 2 patients were adjudicated to have positive and negative ajmaline challenges, respectively, based on standard ECG criteria. In the ajmaline positive patients, the IEGM T wave amplitude changes were more prominent than those of the IEGM ST segment (-898 ± 463 vs. -55 ± 381 µV, P < 0.05). Furthermore, all of these T wave amplitude changes were in the negative polarity, whereas the change in polarity of the ST segment was mixed. The changes in the IEGM T wave amplitude and ST segment were significantly smaller in the ajmaline negative patients compared with those in the ajmaline positive patients [211 ± 158 (P < 0.05) and 107 ± 54 (P < 0.05) µV, respectively). Over all 14 analysable patients, the change in the ECG ST segment over the timecourse of the ajmaline challenge correlated better with the IEGM T wave amplitude change (R = 0.72 ± 0.33) than the IEGM ST segment change (R = 0.63 ± 0.33). Applying an IEGM T wave amplitude change cut-off of 400 µV for predicting the outcome of the ajmaline challenge yielded 92% sensitivity (11/12) and 100% specificity (2/2).ConclusionIn Brugada patients, ajmaline challenge elicits significant T wave amplitude changes within the ICD IEGM, greater than those of the IEGM ST segment. This study is the first step to provide new tools able to continuously monitor the type I Brugada aspect in patients affected by the Brugada syndrome.Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2013. For permissions please email: journals.permissions@oup.com.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.