- Claudia M Dillier, Daniel Trachsel, Werner Baulig, Claudine Gysin, Andreas C Gerber, and Markus Weiss.
- Department of Anesthesia, University Children's Hospital, Zurich, Switzerland.
- Can J Anaesth. 2004 Jan 1;51(1):72-5.
PurposeTo present a case of laryngeal damage in an infant caused by a too large and inappropriately designed cuffed tracheal tube.Clinical FeaturesA 13-month-old child undergoing cardiac surgery was intubated with an uncuffed endotracheal tube with an internal diameter (ID) of 4.0 mm. Because of an important air leak around the tracheal tube during mechanical ventilation, a cuffed endotracheal tube ID 4.0 mm was inserted. The air leak with the tube cuff not inflated was acceptable at 25 cm H2O airway pressure. After extubation on the third postoperative day, the patient showed increasing stridor and respiratory deterioration. Fibreoptic laryngoscopy of the spontaneously breathing patient showed a large intra-laryngeal web. After surgical removal of the web, the child rapidly recovered and was discharged from the hospital on the 12th postoperative day. Inspection of the 4.0 mm (ID) cuffed tracheal tube revealed a cuff positioned inappropriately high and an increase of 0.7 mm in outer tube diameter compared to the 4.0 mm (ID) uncuffed tracheal tube from the same manufacturer. The tube cuff is likely to be situated within the larynx when placed in accordance to insertion depth formulas or radiological criteria, as used for uncuffed tracheal tubes in children.ConclusionThe larger than expected tracheal tube with its intra-laryngeal cuff position in a 13-month-old child likely caused mucosal damage and an inflammatory reaction within the larynx resulting in granulation tissue formation and fibrous healing around the tracheal tube.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.