-
- Quentin Lefebvre, Thomas Vandergoten, Eric Derom, Emilie Marchandise, and Giuseppe Liistro.
- Institute of Mechanics, Materials and Civil Engineering, Louvain School of Engineering, Université Catholique de Louvain, Louvain-la-Neuve, Belgium.
- Respir Care. 2014 Dec 1;59(12):1895-904.
BackgroundThe performance of spirometers is often measured only under ideal conditions, with a mechanical simulator reproducing the expiratory standard American Thoracic Society (ATS) curves generated by a computer. Studies have questioned the value of these results in real-life conditions. The aim of this study was to evaluate the accuracy and precision of 5 office spirometers with a flow-volume simulator using the ATS curves and using flow-volume curves obtained from patients.MethodsWe measured the FVC, peak expiratory flow, and FEV1 by simulating different dynamic waveforms applied by a computer-driven syringe, the Hans Rudolph flow-volume simulator. In addition to testing standard curves recommended by the ATS, we also tested curves obtained with subjects.ResultsThe precision of the office spirometers was good and comparable using the standard ATS curves. One device presented the best performances in terms of accuracy and precision according to the ATS recommendations, but we observed significant biases in all devices with Bland-Altman analysis, particularly with the curves obtained from subjects with severe COPD.ConclusionsThe global quality of most spirometers makes them acceptable for the detection of pulmonary diseases. However, we demonstrated accuracy issues not shown by the standard testing procedure. We propose to improve the testing of spirometers by implementing more realistic flow-volume curves and to refine the analysis of the results.Copyright © 2014 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.