• Ann. Thorac. Surg. · Aug 2012

    Sutureless aortic valve replacement: first-year single-center experience.

    • Giuseppe Santarpino, Steffen Pfeiffer, Joachim Schmidt, Giovanni Concistrè, and Theodor Fischlein.
    • Department of Cardiac Surgery, Klinikum Nürnberg, Nuremberg, Germany. g.santarpino@libero.it
    • Ann. Thorac. Surg. 2012 Aug 1;94(2):504-8; discussion 508-9.

    BackgroundSutureless aortic bioprostheses bear the potential of easy implantation, reduced ischemic time, and surgical trauma in aortic valve replacement. We herein show our clinical and echocardiographic results after a 1-year experience with a new sutureless bioprosthesis.MethodsThe Perceval S (Sorin Biomedica Cardio Srl, Saluggia, Italy) is a pericardial aortic prosthesis assembled within a super-elastic alloy frame. It is implanted intra-annularly, without the need of suture. As part of a premarketing multicenter study (Cavalier Trial), since March 2010, 83 patients were screened for implantation in our center.ResultsThe patients received a size S (4), M (38), or L (41) prosthesis, either as isolated (57) or combined procedures (26). Fifty-one patients (61.5%) received a "J" sternotomy. Mean logistic European system for cardiac operative risk evaluation was 10.±7.5%, mean aortic cross-clamp time was 43.8±20.8 minutes (36±12.7 minutes for isolated procedures). Mean implantation time was 8±3.8 minutes (range 4 to 28 minutes). In-hospital mortality was 2.4% (1 patient for multiorgan failure and 1 for liver insufficiency); mean hospital stay was 11.5±4.4 days (range 2 to 28 days). We recorded 5 pacemaker implantations (6%). At follow-up, we had 2 deaths (1 patient for congestive heart failure and 1 for gastrointestinal bleeding). At 1 year, mean New York Heart Association functional class was 1.0±0.6. Mean transprosthetic gradients were 13.4±2.8, 12.6±2.3, and 10.8±1.3 mm Hg postoperatively, at 6 months, and at 1 year, respectively.ConclusionsThe Perceval S shows satisfactory clinical and hemodynamic results. Due to its simple implantation technique, it represents an alternative especially for minimally invasive surgery. Operative trauma can be minimized by short aortic cross-clamp time.Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…