• Spine · Apr 2016

    Use of Supplemental Short Pre-Contoured Accessory Rods and Cobalt Chrome Alloy Posterior Rods Reduces Primary Rod Strain and Range of Motion Across the Pedicle Subtraction Osteotomy Level: An In Vitro Biomechanical Study.

    • Dennis Winge Hallager, Martin Gehrchen, Benny Dahl, Jonathan A Harris, Manasa Gudipally, Sean Jenkins, Ai-Min Wu, and Brandon S Bucklen.
    • *Department of Orthopaedic Surgery, Copenhagen University Hospital, Copenhagen, Denmark†Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, PA‡Department of Spinal Surgery, 2nd Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
    • Spine. 2016 Apr 1; 41 (7): E388-95.

    Study DesignIn vitro cadaveric biomechanical study.ObjectiveTo assess effects of 4-rod reconstruction, rod material, and anterior column support on motion and surface rod strain in a pedicle subtraction osteotomy model.Summary Of Background DataPedicle subtraction osteotomy (PSO) can correct significant sagittal deformity of the lumbar spine; however, revision rates are high. To reduce rod strain and the incidence of rod fracture, clinical use of multi-rod construction, cobalt chrome (CoCr) alloy rods, and interbody spacers adjacent to PSO has been proposed. Investigating both motion and rod strain is necessary to determine the biomechanical efficacy of these techniques.MethodsFive specimens (T12-S1) underwent PSO at L3 with pedicle screw stabilization at L1-S1. Pedicle subtraction was adjusted to achieve a final lordosis of 70°. Flexion-extension (FE), lateral bending, and axial rotation were applied. Linear strain gauges measured surface rod strain during FE on primary and accessory rods at PSO level. Testing evaluated (1) accessory rods (4-Rod) added at PSO level versus primary rods (2-Rod); (2) Ti versus CoCr rods; and (3) lateral interbody spacers (S) inserted adjacent to PSO. One-way and three-way analysis of variance was performed (P ≤ 0.05).ResultsAll constructs significantly reduced FE and lateral bending motion relative to intact (P < 0.001). The main effect of accessory rods in reducing FE motion was significant (P = 0.021). Accessory and CoCr rods reduced relative surface strain on the primary rod, irrespective of construct (P < 0.001). CoCr 4-Rod + S provided the greatest reduction in strain (76% decrease; P = 0.003).ConclusionAccessory and CoCr rods provided greatest reduction in motion and rod strain at PSO level. Interbody devices minimally affected motion-induced strain and might act primarily to maintain disc height. Clinicians must assess whether surface strain and motion reduction minimize the incidence of rod fracture.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.