Intensive care medicine · Jan 1993
Case ReportsA rare complication of the use of a finger cot to protect the cuff of a tracheal tube during nasotracheal intubation.
- J P Barras, P Bigler, and A Czerniak.
- Department of Visceral Surgery and Transplantation, University of Berne, Inselspital, Switzerland.
- Intensive Care Med. 1993 Jan 1;19(3):174-5.
AbstractSome anesthetists in Switzerland and elsewhere use a finger cot to protect the cuff of the endotracheal tube during nasotracheal intubation. In the presented report the finger cut was lost during the procedure and the patient presented 3 months later with a lateral neck mass. The finger cot was found within that mass at exploration. Apart from the other potential risks of this manoeuvre, this severe complication should incite caution against the practice described above.