-
J Clin Monit Comput · Jun 2015
The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation.
- Koichi Suehiro, Katsuaki Tanaka, Tokuhiro Yamada, Tadashi Matsuura, Takashi Mori, Tomoharu Funao, and Kiyonobu Nishikawa.
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka City, Osaka, 545-8586, Japan, suehirokoichi@yahoo.co.jp.
- J Clin Monit Comput. 2015 Jun 1; 29 (3): 333-9.
AbstractThis study was aimed at comparing the cardiac output (CO) measured by the Vigileo™-FloTrac™ system with that estimated by the thermodilution pulmonary artery catheter (PAC) during one-lung ventilation (OLV) and determining the reliability of this system in tracking phenylephrine-induced CO changes during OLV. Sixteen patients scheduled for descending aorta replacement were enrolled. The study was performed 30 min after starting OLV under stable hemodynamic conditions. We recorded hemodynamic variables, CO measured by PAC thermodilution (ICO), CO measured by Vigileo™-FloTrac™ system (Version 3.02, Edwards Lifesciences, Irvine, CA, USA) (APCO), and systemic vascular resistance index (SVRI) before (T0) and after (T1) phenylephrine (100 μg) administration. We used Bland-Altman analysis to compare ICO and APCO. Polar plot and four-quadrant plot were used to assess the tracking ability of the Vigileo™-FloTrac™ system against ICO after administration of phenylephrine. Ninety hemodynamic interventions were performed. Bland-Altman analysis revealed that the mean bias between APCO and ICO was 0.05 L/min and the percentage error, 46.9 %. Four-quadrant plot analysis showed a concordance rate of 24.7 %, while polar plot analysis showed that the concordance rate was 13.3 %; the angular bias, -45.9°; radial limit of agreement, 85.3°. The bias between APCO and ICO was significantly correlated with the SVRI value (p < 0.001, r(2) = 0.822). The reliability of the Vigileo™-FloTrac™ system during OLV to estimate CO and track phenylephrine-induced CO changes was not acceptable.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.