• J Hand Surg Am · Sep 2012

    Comparative Study

    Interfragmentary compression profile of 4 headless bone screws: an analysis of the compression lost on reinsertion.

    • A W Gardner, Y T Yew, P Y Neo, C C Lau, and S C Tay.
    • Department of Hand Surgery, Singapore General Hospital, Singapore.
    • J Hand Surg Am. 2012 Sep 1;37(9):1845-51.

    PurposeTo evaluate the interfragmentary compression force generated by 4 different types of headless compression screws and to examine the effects of removal and reinsertion of the screw.MethodsWe chose foot bones rather than scaphoids for the model because they were larger and would enable comparison of 2 screw designs in the same bone, thereby controlling for the effect of interspecimen variability. A transverse osteotomy was made in 10 fresh-frozen cadaveric navicular bones and 10 medial cuneiforms. A load cell was used to measure compression between the 2 fragments as a screw was inserted across the fracture. Each bone was tested twice, with an Acutrak Mini (Acumed, Hillsboro, OR; n = 10) and an SBi AutoFIX screw (SBi, Morrisville, PA; n = 10) or an Extremifix (Osteomed, Addison, TX; n = 10) and a Barouk screw (Depuy, Warsaw, IN; n = 10). Compression was recorded at initial insertion and on removal and reinsertion of the screw twice to the same position. Compression was also measured after one additional full turn further than the initial position.ResultsThe mean interfragmentary compression generated by the Acutrak Mini screw was greater than that of the SBi AutoFIX screw (96 N vs 22 N). There was a trend toward a greater mean compression generated by the Extremifix screw compared to the Barouk screw (85 N vs 22 N). There was a significant loss of compression upon removal and reinsertion of the screws. An additional full turn of the screw was able to re-establish a large proportion of the original compression.ConclusionsThe compression forces achieved by headless screw systems appeared to vary according to the screw design, depth of insertion, and the quality of the bone. Substantial compression was lost if the screw was removed and replaced. Some screw designs appeared to require a greater depth of insertion to achieve effective compression, and the number of additional turns required to re-establish compression might vary according to the thread design.Clinical RelevanceSurgeons should be aware of the compression profile of each screw design and the effect of screw removal and reinsertion in the clinical setting of small bone fixation.Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…