• Psychiat Danub · Dec 2014

    The Results of Internal Fixation of Proximal Humeral Osteoporotic Fractures with PHILOS Locking Plate.

    • Ante Bandalović, Fabijan Cukelj, Josip Knežević, Marko Ostojić, Arsen Pavić, Zlatko Parać, and Matko Rošin.
    • University Hospital Split, Department of Traumatology, 21 000 Split, Croatia.
    • Psychiat Danub. 2014 Dec 1; 26 Suppl 2: 376-81.

    BackgroundIn the last fifty years since plate and screw osteosynthesis has been implemented in fracture treatment, osteosporotic bone fractures were observed as a special problem. Due to special histologic, anatomic, physical and biomehanic properties of osteoporotic changed bone the laws of biomechanics suggest that stable osteosynthesis for osteoporotic bone is necessary to increase the contact surface of metallic implants and bone and the stability of the screw-plate-bone compound. There are numerous surgical techniques and methods for treatment of osteoporotic proximal humeral fractures. Every surgical procedure has to establish anatomical reduction and stable fixation that will enable early mobilisation.Subjects And MethodsThe aim of this study was to present results of internal fixation of proximal humeral osteoporotic fractures with PHILOS locking plate. Between 2007 and 2012, a total of 67 patients older than 65 years with closed proximal humerus fractures underwent surgical treatment with PHILOS plate system (Synthes, Switzerland). 42 patients were operated with deltopectoral approach and 25 with deltoid split approach. After a mean follow up period of 14.68 (6-28) months functional and radiologic results were assessed.ResultsWe noted 9 postoperative complications related to surgical technique (1 intraarticular screw placement, 1 displacement in major tuberculum fragment, 1 displacement in major tuberculum fragment along with oblique placement of the plate, 2 cases of inadequate reduction, 1 case of humeral head avascular necrosis, varus humeral head fixation in 3 cases). None of the patients developed superficial or deep surgical infection. There was no nonunions. In the final evaluation, the Constant shoulder score was 91.75 (72-100).ConclusionsIn this study PHILOS locking plate showed good applicability, respecting bone biologic properties because of negligible interference with blood supply of the humeral head. There was no requirement to shape the plate enabling stabilization at constant angles as clear benefit of this plate. All that enables early mobilisation, and no implant insufficiency resulting in satisfactory treatment results and high Constant shoulder scores.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…