- G Lin, R A Nishimura, B J Gersh, D Phil, S R Ommen, M J Ackerman, and P A Brady.
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905, USA.
- Heart. 2009 May 1;95(9):709-14.
BackgroundAlthough the benefit of implantable cardioverter defibrillator (ICD) therapy in patients with hypertrophic cardiomyopathy (HCM) at risk for sudden cardiac arrest is well established, there may be a higher risk for device complications and inappropriate shocks.ObjectivesTo determine the incidence of inappropriate ICD shocks and device complications in HCM patients and the impact of young age at ICD implant and atrial fibrillation.MethodsHCM patients who underwent ICD implantation between January 1988 and December 2005 were included. The frequency of device complications, including pneumothorax, pericardial effusion, haematoma, lead revisions, infection and rate of inappropriate shocks, was determined. ICD shocks were characterised as inappropriate if triggered by sinus tachycardia, atrial fibrillation or device malfunction.ResultsA total of 181 patients were included (mean age 44 (SD 17) years; 62% males). During a mean follow-up of 59 (42) months (4.92 years; 830.75 patient-years), 65 patients (36%) had a total of 88 device complications, including 42 (23%) patients with inappropriate shocks. The rate of inappropriate shocks was 5.3% per year (vs 4% risk of appropriate shocks), and the likelihood of inappropriate ICD shocks per 100 patient-years was 5.1. Younger age and atrial fibrillation were associated with an increased risk of inappropriate ICD discharges.ConclusionsThe rate of inappropriate ICD shocks and frequency of device complications in HCM patients are not insignificant and are most common in younger patients and those with atrial fibrillation. Inappropriate ICD shocks are the most common device complication and should be accounted for when counselling high-risk HCM patients for ICD implantation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.