Regional anesthesia · Jan 1997
ReviewIdentification of the epidural space: is loss of resistance to air a safe technique? A review of the complications related to the use of air.
- L R Saberski, S Kondamuri, and O Y Osinubi.
- Yale Center for Pain Management, Yale University School of Medicine, New Haven, Connecticut 06510, USA.
- Reg Anesth. 1997 Jan 1;22(1):3-15.
Background And ObjectivesThe major determinant of successful epidural anesthesia is the localization of the epidural space. The manual loss of resistance technique is widely used by anesthesiologists in identifying the epidural space. Should air or saline be used in detecting the point of loss of resistance? No consensus exists as to which technique is superior, and individual providers currently use the technique with which they are most comfortable. The incidence of adverse effects associated with the use of epidural air is unknown and may be underreported as the effects may be unrecognized or considered trivial. The authors comprehensively review the complications of epidural air from published reports.MethodsUsing the appropriate key words, the authors searched the Medline (National Library of Congress) scientific data bank from 1966 to 1995, for case reports of epidural complications.ResultsThere are few prospective, controlled, double-blinded studies comparing the relative merits of using air versus saline for the loss of resistance technique of epidural placement. There are, however, numerous case reports. Complications associated with the use of air for the loss of resistance technique included pneumocephalus, spinal cord and nerve root compression, retroperitoneal air, subcutaneous emphysema, and venous air embolism. Additionally, inadequate analgesia and paresthesia have been associated with the loss of resistance technique using air. Transient and permanent neurologic sequelae have been attributed to some of the complications. The simultaneous administration of nitrous oxide and positive. Pressure ventilation has also been reported to expand localized collections of air, resulting in heightened symptoms.ConclusionsThe potential complications associated with the use of air for identifying the epidural space with the loss of resistance technique may outweigh the benefits. The use of saline to identify the epidural space may help to reduce the incidence of these complications.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.