J. Cardiothorac. Vasc. Anesth. · Jun 1999
Reliability of continuous jugular venous bulb hemoglobin oxygen saturation during cardiac surgery.
- E Anastasiou, K Gerolioliou, K Karakoulas, M Peftoulidou, and M Giala.
- Department of Anesthesia, AHEPA University Hospital, Thessaloniki, Greece.
- J. Cardiothorac. Vasc. Anesth. 1999 Jun 1;13(3):276-9.
ObjectiveTo evaluate the accuracy and reliability of continuous measurement of jugular venous bulb hemoglobin oxygen saturation (SjvO2) with a fiberoptic catheter (SjvO(2OX)) during cardiac surgery versus simultaneous paired measurements of hemoglobin oxygen saturation by the Hemoximeter (SjVO(2HEM); Radiometer, Copenhagen, Denmark) and indirect estimations of hemoglobin oxygen saturation from measurements of partial pressure of oxygen in blood gases (SjVO(2BG)).DesignA prospective study.SettingAmerican Hellenic Educational Progressive Association General Hospital, University Hospital of Thessaloniki, Greece.PatientsThirty patients undergoing elective aortocoronary artery bypass surgery.InterventionsIn addition to routine pressure monitoring, a 4F fiberoptic catheter was placed in the left jugular bulb by a retrograde internal jugular vein approach and SIvO(2OX) was continuously measured. Before insertion, each catheter was calibrated in vitro.Measurements And Main ResultsOne hundred twelve simultaneous paired recordings between SjvO(2OX) and SjVO2BG were performed to define the accuracy of SjVO(2OX) to SjVO(2BG). Sixty-one of 112 simultaneous paired recordings between SjvO(2OX) and SjVO(2HEM) and SjVO(2HEM) and SjVO(2BG) were performed to define the accuracy of SjvO(2OX) to the reference SjVO(2HEM) and the reliability of the SjVO(2BG) measurement to SjVO(2HEM). The fiberoptic catheter readings varied from underestimating to overestimating hemoglobin saturation by a mean of -5.35% to +9.67% and of -3.22% to +7.81% versus Blood Gas Analyzer (Ciba-Corning) and Co-Oximeter (OSM 2b Hemoximeter, Radiometer) values, respectively. The mean underestimation and overestimation of Co-Oximeter versus Blood Gas Analyzer values were -3.18% and +4.17%, respectively.ConclusionSjvO2 values obtained continuously from a jugular venous bulb fiberoptic catheter may give relatively accurate readings provided they are duly interpreted and errors caused by wall artifact or blood sampling are avoided.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.