• Heart · Aug 2012

    Comparative Study

    Combined use of optical coherence tomography and intravascular ultrasound imaging in patients undergoing coronary interventions for stent thrombosis.

    • Fernando Alfonso, Jaime Dutary, Manuel Paulo, Nieves Gonzalo, Maria J Pérez-Vizcayno, Pilar Jiménez-Quevedo, Javier Escaned, Camino Bañuelos, Rosana Hernández, and Carlos Macaya.
    • Department of Interventional Cardiology, Cardiovascular Institute, Clínico San Carlos University Hospital, Madrid, Spain. falf@hotmail.com
    • Heart. 2012 Aug 1;98(16):1213-20.

    ObjectiveThis prospective study sought to assess the diagnostic value of optical coherence tomography (OCT) compared with intravascular ultrasound (IVUS) in patients presenting with stent thrombosis (ST).Design And SettingAlthough the role of IVUS in this setting has been described, the potential diagnostic value of OCT in patients suffering ST remains poorly defined. Catheterization Laboratory, University Hospital.Patients And InterventionsFifteen consecutive patients with ST undergoing rescue coronary interventions under combined IVUS/OCT imaging guidance were analysed.Mean Outcome MeasuresAnalysis and comparison of OCT and IVUS findings before and after interventions.ResultsBefore intervention, OCT visualised the responsible thrombus in all patients (thrombus area 4.7±2.5 mm(2), stent obstruction 82±14%). Minimal stent area was 4.7±2.1 mm(2) leading to severe stent underexpansion (expansion 60±21%). Although red or mixed thrombus (14 patients) induced partial strut shadowing (total length 12.3±6 mm), malapposition (six patients), inflow-outflow disease (five patients), uncovered struts (nine patients) and associated in-stent restenosis (five patients, four showing neoatherogenesis) was clearly recognised. IVUS disclosed similar findings but achieved poorer visualisation of thrombus-lumen interface and strut malapposition, and failed to recognise uncovered struts and associated neoatherosclerosis. After interventions, OCT demonstrated a reduced thrombus burden (2.4±1.6 mm(2)) and stent obstruction (24±14%) with improvements in stent area (6.8±2.9 mm(2)) and expansion (75±21%) (all p<0.05). IVUS and OCT findings proved to be complementary.ConclusionsOCT provides unique insights on the underlying substrate of ST and may be used to optimise results in these challenging interventions. In this setting, OCT and IVUS have complementary diagnostic values.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…