• Spine · Feb 2005

    Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years.

    • Dieter Grob, Arnoldo Benini, Astrid Junge, and Anne F Mannion.
    • Spine Unit, Schulthess Klinik, Zürich, Switzerland. gro@kws.ch
    • Spine. 2005 Feb 1;30(3):324-31.

    Study DesignRetrospective study on a consecutive series of patients.ObjectivesTo examine patient-oriented outcome after Dynesys implantation.Summary Of Background DataThe dynamic neutralization system for the spine, Dynesys, is a nonfusion pedicle screw stabilization system, which was developed in an attempt to overcome the inherent disadvantages of rigid instrumentation and fusion. Although the system has been in clinical use for more than 5 years, no studies from disinterested research groups have reported on patient-oriented outcome after surgery with Dynesys.MethodsA total of 50 consecutive patients instrumented with Dynesys over the preceding 40 months were invited to complete a postal, patient-oriented follow-up questionnaire. The data from 31 of 31 of these, with at least 2 years' follow-up, were analyzed (mean age, 50 years; SD, 13 years; 20 women, 11 men). The primary indication for surgery was degenerative disease (disc/stenosis) with associated "instability"; 11 of 31 (35%) patients had had prior spinal surgery. In 32% cases, 1 level was instrumented, in 52% 2 levels, 13% 3 levels, and 3% 4 levels. Thirteen of 31 (42%) patients underwent additional decompression.ResultsWithin the 2-year follow-up period, 6 of 31 (19%) patients had required or were scheduled for a further surgical intervention. At follow-up, mean (SD) back and leg pain (0-10 VAS) were 4.7 (3.2) and 3.8 (3.6), respectively. The following global outcomes were reported: back symptoms, 67% improved, 30% same, 3% worse; leg symptoms, 64% improved, 21% same, 14% worse; ability to do physical activities/sports, 40% improved, 33% same, 27% worse; quality of life, 50% improved, 37% same, 13% worse; how much the operation helped, 29% helped a lot, 23% helped, 10% only helped a little, 35% didn't help, 3% made things worse.ConclusionThe results of the present study indicate that both back and leg pain are, on average, still moderately high 2 years after instrumentation with the Dynesys system. Only half of the patients declared that the operation had helped and had improved their overall quality of life; less than half reported improvements in functional capacity. The reoperation rate after Dynesys was relatively high. The results provide no support for the notion that semirigid fixation of the lumbar spine results in better patient-oriented outcomes than those typical of fusion.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…