Cardiovasc Intervent Radiol · Jan 2009
Retrieval of the protection filter with a soft coaxial catheter after carotid stenting.
- Thomas E Mayer, Markus Holtmannspötter, and Stefanie Müller-Schunk.
- Department of Neuroradiology, University Hospital, Friedrich-Schiller-University Jena, Jena, Germany. t.e.mayer@med.uni-jena.de
- Cardiovasc Intervent Radiol. 2009 Jan 1;32(1):136-8.
AbstractThe purpose of this study was to shorten and simplify the procedure of filter retrieval after carotid stenting with cerebral protecting devices. We propose a retrieval method with a soft-tip guiding catheter, which eliminates the step of balloon exchange and introduction of a retriever catheter for the protection filter. The technique was successfully used in our last 60 consecutive patients. One transient deficit occurred. In conclusion, retrieval of the filter with a soft coaxial catheter after carotid stenting is a feasible and safe method and may simplify cerebrovascular protection during stenting.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.