• Spine · Jul 2000

    The effect of kyphosis on the mechanical strength of a long-segment posterior construct using a synthetic model.

    • J Orchowski, D W Polly, W R Klemme, I Oda, and B Cunningham.
    • Orthopaedic Surgery Service, Walter Reed Army Medical Center, Washington, DC 20037-5001, USA.
    • Spine. 2000 Jul 1;25(13):1644-8.

    Study DesignThis experimental study used synthetic spine models to compare the effect of the angle of kyphosis, rod diameter, and hook number on the biomechanical stiffness of a long-segment posterior spinal construct.ObjectiveTo examine the biomechanical effects of incremental kyphosis on variously instrumented long-segment posterior spinal constructs.Summary Of Background DataEuler's formula for loading of curved long columns would suggest that kyphosis has a profound impact on the biomechanical behavior of long-segment posterior spinal constructs. The effects of sagittal contour on the mechanical properties of long-segment posterior spinal constructs have not been well documented.MethodsKyphotic and straight synthetic spine models were used to test long-segment posterior instrumentation constructs biomechanically while varying rod diameter and the number of hook sites. The synthetic spines, composed of polypropylene vertebral blocks and isoprene elastomer intervertebral spacers, were fabricated with either 0 degrees, 27 degrees, or 53 degrees of sagittal contour. The models were instrumented with 5.5- or 6.35-mm titanium rods, and with either 8 or 12 hooks. The models were loaded from 0 to 300 N in a cyclical ramp fashion using an MTS 858 Bionix testing device testing device. Construct stiffness (force and displacement) during axial compression was determined.ResultsStraight model: Changing the hook number from 8 to 12 caused a 32% increase in construct stiffness with the 5.5-mm rod. Changing the rod diameter from 5.5 to 6.35 mm caused a 36% increase in construct stiffness with the 8-hook pattern. Changing both the rods and hooks caused the stiffness to increase 44%. 27 degreesModelChanging the hook number from 8 to 12 caused a 20% increase in construct stiffness with the 6.5-mm rod. Changing the rod diameter from 5.5 to 6.35 mm caused a 29% increase in construct stiffness with the 12-hook pattern. Changing both the rods and hooks caused the construct stiffness to increase 26%. 53 degreesModelChanging the hook number from 8 to 12 caused a 14% increase in construct stiffness with the 6.35-mm rod. Changing the rod diameter from 5.5 to 6.35 mm caused a 17% (P<0.0005) increase in construct stiffness with the 12-hookpattern. Changing both rods and hooks caused the stiffness to increase 21%. Summary data on angular kyphosis: Using the same rod diameter and the same number of hooks, and progressing from a straight alignment to 27 degrees of sagittal contour decreased construct stiffness 32%. Going from straight alignment to 53 degrees decreased the stiffness 59.6%. All reported values were statistically significant (P < 0.0005).ConclusionsThe biomechanical stiffness of the straight spine was sensitive to both an increase in hook fixation sites and an increase in rod diameter. The kyphotic spines, however, were more sensitive to variations in rod diameter. Although with increasing kyphosis, the optimum instrumentation strategy will maximize both rod diameter and the number of hook sites, instrumented kyphotic spines remain biomechanically "disadvantaged" as compared with nonkyphotic instrumented spines.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…