• Br J Anaesth · Jan 2015

    Randomized Controlled Trial

    A randomized, triple-masked, active-controlled investigation of the relative effects of dose, concentration, and infusion rate for continuous popliteal-sciatic nerve blocks in volunteers.

    • S J Madison, A M Monahan, R R Agarwal, T J Furnish, E J Mascha, Z Xu, M C Donohue, A C Morgan, and B M Ilfeld.
    • Department of Anesthesiology, University of California San Diego, 200 West Arbor Drive, MC 8770, San Diego, CA 92103-8770, USA.
    • Br J Anaesth. 2015 Jan 1; 114 (1): 121-9.

    BackgroundIt remains unknown whether local anaesthetic dose is the only factor influencing continuous popliteal-sciatic nerve block effects, or whether concentration, volume, or both exert an influence as well.MethodsBilateral sciatic catheters were inserted in volunteers (n=24). Catheters were randomly assigned to ropivacaine of either 0.1% (8 ml h(-1)) or 0.4% (2 ml h(-1)) for 6 h. The primary endpoint was the tolerance to transcutaneous electrical stimulation within the tibial nerve distribution at hour 6. Secondary endpoints included current tolerance at other time points and plantar flexion maximum voluntary isometric contraction (22 h total).ResultsAt hour 6, tolerance to cutaneous stimulation for limbs receiving 0.1% ropivacaine was [mean (standard deviation)] 27.0 (20.2) vs26.9 (20.4) mA for limbs receiving 0.4% [estimated mean difference 0.2 mA; 90% confidence interval (CI) -8.2 to 8.5; P=0.02 and 0.03 for lower and upper boundaries, respectively]. Because the 90% CI fell within the prespecified tolerance ±10 mA, we conclude that the effect of the two concentration/volume combinations were equivalent. Similar negative findings were found for the secondary outcomes.ConclusionsFor continuous popliteal-sciatic nerve blocks, we found no evidence that local anaesthetic concentration and volume influence block characteristics, suggesting that local anaesthetic dose (mass) is the primary determinant of perineural infusion effects in this anatomic location. These findings suggest that for ambulatory perineural local anaesthetic infusion-for which there is usually a finite local anaesthetic reservoir-decreasing the basal rate while increasing the local anaesthetic concentration may allow for increased infusion duration without compromising postoperative analgesia.Clinical Trial RegistrationNCT01898689.© The Author 2014. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.