• Sleep · Aug 2011

    Response of genioglossus muscle to increasing chemical drive in sleeping obstructive apnea patients.

    • Andrea H S Loewen, Michele Ostrowski, John Laprairie, Frances Maturino, Patrick J Hanly, and Magdy Younes.
    • Sleep Center, Foothills Medical Centre, University of Calgary, Calgary, Alberta, Canada.
    • Sleep. 2011 Aug 1;34(8):1061-73.

    Study ObjectivesSubjects with a collapsible upper airway must activate their pharyngeal dilators sufficiently in response to increasing chemical drive if they are to maintain airway patency without arousal from sleep. Little is known about the response of pharyngeal dilators to increasing chemical drive in these subjects. We wished to determine, in obstructive apnea patients, the response of the genioglossus to increasing chemical drive and the contribution of mechanoreceptor feedback to this response.DesignPhysiological study.SettingUniversity-based sleep laboratory.Patients20 patients with obstructive apnea.InterventionsGenioglossus activity was monitored during overnight polysomnography on optimal continuous positive airway pressure (CPAP). Intermittently, inspired gases were altered to produce different levels of ventilatory stimulation. CPAP was then briefly reduced to 1.0 cm H(2)O (dial-down), inducing an obstruction.Measurements And ResultsWithout mechanoreceptor feedback (i.e., on CPAP) the increase in genioglossus activity as ventilation increased from 6.1 ± 1.4 to 16.1 ± 4.8 L/min was modest (ΔTonic activity 0.3% ± 0.5%maximum; ΔPhasic activity 1.7% ± 3.4%maximum). Genioglossus activity increased immediately upon dial-down, reflecting mechanoreceptor feedback, but only when ventilation before dial-down exceeded a threshold value. This threshold varied among patients and, once surpassed, genioglossus activity increased briskly with further increases in chemical drive (1.1% ± 0.84%GG(MAX) per L/min increase in V(E)).ConclusionsIn sleeping obstructive apnea patients: (1) Mechanoreceptor feedback is responsible for most of the genioglossus response to chemical drive. (2) Mechanoreceptor feedback is effective only above a threshold chemical drive, which varies greatly among patients. These findings account in part for the highly variable relation between pharyngeal mechanical abnormalities and apnea severity.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.