• Heart · May 2005

    Case Reports

    Coronary air embolism treated with aspiration catheter.

    • M S Patterson and F Kiemeneij.
    • Amsterdam Department of Interventional Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, the Netherlands. markspatterson@doctors.net.uk <markspatterson@doctors.net.uk>
    • Heart. 2005 May 1;91(5):e36.

    AbstractCoronary air embolism remains a recognised complication of coronary catheterisation despite a strong emphasis on prevention. Current treatment consists of supportive measures with 100% oxygen and analgesia. Recent case reports describe the use of mechanical treatments aimed at dispersing or removing the air embolus with variable success. A case of coronary air embolism causing an acute coronary syndrome is described that was definitively treated with an aspiration system. The effectiveness of the aspiration system in the distal section of an obtuse marginal artery indicates that such dedicated aspiration systems may prove useful in the standard treatment of air embolism.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…