    Resistance of Colorimetric Carbon Dioxide Detectors Commonly Utilized in Neonates.

    • Melissa K Brown, Danielle V Lazarus, Sarah R Gonzales, Wade D Rich, Madeline J Wozniak, Debra M Poeltler, and Anup C Katheria.
    • Neonatal Research Institute, Sharp Mary Birch Hospital for Women and Newborns, San Diego, California. melissa.brown@sharp.com.
    • Respir Care. 2016 Aug 1; 61 (8): 1003-7.

    BackgroundColorimetric end-tidal carbon dioxide (ETCO2) detectors can identify airway obstruction during noninvasive ventilation and successful intubation during newborn resuscitation. The resistance of these devices is not well described, and the information provided by manufacturers is incomplete.MethodsWe compared the resistance of 3 colorimetric ETCO2 detectors (Neo-StatCO2, Pedi-Cap, and Mini StatCO2,) and 2 mainstream capnograph sensors (EMMA infant airway adapter 17449 and neonatal/infant airway adapter YG-213T). Endotracheal tubes, 2.5-4.0-mm inner diameter (Portex) were measured as a reference range. A differential pressure transducer was placed between the device and a T-piece resuscitator. The other side of the device was open to air. Resistance to flow was tested at 1-10 L/min. Resistance was calculated as the change in pressure over change in flow and expressed as cm H2O/L/s.ResultsThere was a significantly higher mean resistance across all flows tested for the Neo-StatCO2 compared with the other ETCO2 devices (P < .001). There was a 6-fold difference between the least and most resistive colorimetric detectors. At the commonly utilized flow of 10 L/min, the resistance of the Neo-StatCO2 was 61.1 cm H2O/L/s, comparable with that of a 3.0 endotracheal tube, which we measured at 62.7 cm H2O/L/s. The resistance values of the Pedi-Cap and Mini StatCO2 were 9.9 and 8.4 cm H2O/L/s, respectively. Those of the EMMA and YG-213T were 7.1 and 2.6 cm H2O/L/s, respectively.ConclusionsWe found significant differences in resistance between devices used to detect ETCO2 during resuscitation of premature infants. Future trials are needed to determine the effects of this resistance on work of breathing, particularly on very premature newborns receiving mask CPAP.Copyright © 2016 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.