• J Clin Monit Comput · Dec 1999

    Comparative Study Clinical Trial

    Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique.

    • A Johansson, P A Oberg, and G Sedin.
    • Department of Biomedical Engineering, Linköping University, Sweden.
    • J Clin Monit Comput. 1999 Dec 1; 15 (7-8): 461-7.

    ObjectiveA new photoplethysmographic (PPG) device for respiratory and heart rate monitoring has been evaluated in the neonatal care units at the University Children's Hospital of Uppsala, Sweden. The purpose of this study was to compare this new device with more established techniques, i.e., transthoracic impedance plethysmography (TTI) for monitoring of respiratory rate and ECG for heart rate monitoring.MethodsData were acquired continuously for 8-hours in each of 6 neonates. The signals were analysed for periods of 30 seconds, in which the heart and respiratory signals from the PPG device were compared with the ECG and the impedance plethysmogram.ResultsThe ECG recordings were of high quality in 77% of the analysed periods. In these periods, excluding periods (6%) disturbed by offset-adjustement of the PPG signal, the PPG heart signal included 1.1% (+/- 0.7% SD) false negative beats and 0.9% (+/- 0.6%) false positive beats. In periods with an impedance signal of high quality (29% of total time), the part of the PPG signal synchronous with respiration included 2.7% (+/- 1.1%) false negative breaths and 1.5% (+/- 0.4%) false positive breaths. Here, 2% of the periods were discarded because of offset-adjustment. From the periods of low signal quality, two other conclusions were drawn: 1) The impedance signal contains more power in the respiratory range than the corresponding PPG respiratory signal. 2) The breaths are easier to identify in the PPG respiratory signal than in the impedance signal (subjective measure).ConclusionsElectrode and motion artefacts seem to disturb the ECG signals and, particularly, the impedance signals. During periods of high quality ECG and impedance signals, the new optical device produces signals of equal quality to these traditional methods, and is in some cases even better. The new device is non-invasive and has a small optical probe. These factors indicate further advantages of the photoplethysmographic method.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…