• Can Assoc Radiol J · Nov 2014

    Reduced kilovoltage in computed tomography-guided intervention in a community hospital: effect on the radiation dose.

    • Saman Rezazadeh, Steven J Co, and Simon Bicknell.
    • Department of Internal Medicine, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
    • Can Assoc Radiol J. 2014 Nov 1;65(4):345-51.

    PurposeThe purpose of this study was to determine whether low-kilovoltage (80 or 100 kV) computed tomography (CT)-guided interventions performed in a community-based hospital are feasible and to compare radiation exposure incurred with conventional 120 kV potential.Materials And MethodsEffective doses (ED) received by patients who underwent CT-guided intervention were analysed before and after a low-dose kilovoltage protocol was instituted in our department. We performed CT-guided procedures of 93 consecutive patients by using conventional 120-kV tube voltage (50 patients) and a low voltage of 80 or 100 kV for the remainder of this cohort. Automatic tube current modulation was enabled to obtain the best image quality. Procedure details were prospectively recorded and included examination site and type, slice width, tube voltage and current, dose length product, volume CT dose index, and size-specific dose estimate. Dose length product was converted to ED to account for radiosensitivity of specific organs. Statistical comparisons with test differences in the ED, volume CT dose index, size-specific dose estimate, and effective diameter (patient size) were made by using the Student t test.ResultsAll but 6 of the procedures performed at 80 kV were successful, for a success rate of 86%. At lower voltages, the ED was significantly (P < .01) reduced, on average, by 57%, 73%, and 65% for the pelvic, chest, and abdomen procedures, respectively.ConclusionA low-dose radiation technique by using 80 or 100 kV results in a high technical success rate for pelvic, chest, and abdomen CT-guided interventional procedures, although dramatically decreasing radiation exposure. There was no significant difference in effective diameter (patient size) between the conventional and the low-dose groups, which would suggest that dose reduction was indeed a result of kVp change and not patient size.Copyright © 2014 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…