• BMC emergency medicine · Jan 2008

    Case Reports

    An evaluation of the osmole gap as a screening test for toxic alcohol poisoning.

    • Larry D Lynd, Kathryn J Richardson, Roy A Purssell, Riyad B Abu-Laban, Jeffery R Brubacher, Katherine J Lepik, and Marco L A Sivilotti.
    • Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC, Canada. llynd@interchange.ubc.ca
    • BMC Emerg Med. 2008 Jan 1;8:5.

    BackgroundThe osmole gap is used routinely as a screening test for the presence of exogenous osmotically active substances, such as the toxic alcohols ethylene glycol and methanol, particularly when the ability to measure serum concentrations of the substances is not available. The objectives of this study were: 1) to measure the diagnostic accuracy of the osmole gap for screening for ethylene glycol and methanol exposure, and 2) to identify whether a recently proposed modification of the ethanol coefficient affects the diagnostic accuracy.MethodsElectronic laboratory records from two tertiary-care hospitals were searched to identify all patients for whom a serum ethylene glycol and methanol measurement was ordered between January 1, 1996 and March 31, 2002. Cases were eligible for analysis if serum sodium, blood urea nitrogen, glucose, ethanol, ethylene glycol, methanol, and osmolality were measured simultaneously. Serum molarity was calculated using the Smithline and Gardner equation and ethanol coefficients of 1 and 1.25 mOsm/mM. The diagnostic accuracy of the osmole gap was evaluated for identifying patients with toxic alcohol levels above the recommended threshold for antidotal therapy and hemodialysis using receiver-operator characteristic curves, likelihood ratios, and positive and negative predictive values.ResultsOne hundred and thirty-one patients were included in the analysis, 20 of whom had ethylene glycol or methanol serum concentrations above the threshold for antidotal therapy. The use of an ethanol coefficient of 1.25 mOsm/mM yielded higher specificities and positive predictive values, without affecting sensitivity and negative predictive values. Employing an osmole gap threshold of 10 for the identification of patients requiring antidotal therapy resulted in a sensitivity of 0.9 and 0.85, and a specificity of 0.22 and 0. 5, with equations 1 and 2 respectively. The sensitivity increased to 1 for both equations for the identification of patients requiring dialysis.ConclusionIn this sample, an osmole gap threshold of 10 has a sensitivity and negative predictive value of 1 for identifying patients for whom hemodialysis is recommended, independent of the ethanol coefficient applied. In patients potentially requiring antidotal therapy, applying an ethanol coefficient of 1.25 resulted in a higher specificity and positive predictive value without compromising the sensitivity.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…