• J Interv Cardiol · Apr 2014

    Randomized Controlled Trial Multicenter Study Comparative Study

    Comparison of biodegradable polymer versus durable polymer sirolimus-eluting stenting in patients with acute st-elevation myocardial infarction undergoing primary percutaneous coronary intervention: results of the RESOLVE study.

    • Qi Zhang, Jian Ping Qiu, Ajay J Kirtane, Tian Qi Zhu, Rui Yan Zhang, Zhen Kun Yang, Jian Hu, Feng Hua Ding, Run DU, and Wei Feng Shen.
    • Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
    • J Interv Cardiol. 2014 Apr 1;27(2):131-41.

    BackgroundSirolimus-eluting stents (SES) with a biodegradable polymer coating have demonstrated promising results but have not been compared to SES with a durable polymer in high-risk patients. We compared the efficacy of these 2 stent types in patients with acute myocardial infarction (STEMI).MethodsOne thousand one hundred ninety-two STEMI patients were randomized to receive SES coated with biodegradable (n = 596) or durable polymer (n = 596). The study end-point was the composite of major adverse cardiac events (MACE) including all-cause death, recurrent myocardial infarction (MI), or target lesion revascularization (TLR) at 1-year follow-up. Secondary end-points included individual components of primary end-point and stent thrombosis.ResultsCompared with durable polymer SES, the noninferiority of SES with biodegradable polymer coating was established by an absolute risk difference of 0.9% in the primary end-point (12.4% vs. 13.3%, P = 0.67) and an upper limit of one-sided 95% confidence interval (CI) of 2.96% (P for noninferiority = 0.001). Rate of death, recurrent MI, and TLR were 7.9% and 8.6% (HR: 0.92; 95% CI: 0.61-1.38, P = 0.67), 2.9% and 3.5% (HR: 0.80; 95% CI: 0.42-1.54, P = 0.51), and 2.0% and 3.2% (HR: 0.62; 95% CI: 0.30-1.30, P = 0.20) in the biodegradable polymer SES and durable polymer SES group at 1-year clinical follow-up, respectively. Despite similar rates of 30-day ARC definite/probable stent thrombosis, late stent thrombosis (stent thrombosis occurring beyond 30 days) was lower with biodegradable polymer SES (0.7% vs. 2.2%, P = 0.028).ConclusionsIn patients undergoing primary PCI for STEMI, the use of biodegradable polymer SES was associated with noninferior 1-year rates of MACE compared with durable polymer SES.© 2014, Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.