• Journal of wound care · Nov 2007

    Comparative Study

    Evaluation of two absorbent silver dressings in a porcine partial-thickness excisional wound model.

    • A Bell and J Hart.
    • Institute for Molecular and Cellular Biology, University of Leeds, West Yorkshire, UK.
    • J Wound Care. 2007 Nov 1;16(10):445-8, 450-3.

    ObjectiveTo investigate and compare the performance of two widely used silver-containing, fibre-based dressings (Silvercel and Aquacel Ag) in terms of exudate management, wound-site adherence, dressing integrity, retention of dressing debris within wounds, frequency of debris-associated foreign body reactions and the impact of both debris and tissue reactions on wound-tissue integrity.MethodThe dressings were evaluated in a porcine partial-thickness exudating wound model (an in vivo model of moderate to high exudation up to post-wounding day 4, and low exudation from days 4 to 7). Dressing performance was assessed using a panel of semi-quantitative scales.Wound-exudate retention, dressing structure following exposure to exudate, and adherence to wound tissues were compared macroscopically; the extent of trapped dressing debris, any ensuing tissue reactions and the level of resulting tissue disruption were compared histologically.ResultsSilvercel was found to be significantly more effective in terms of wound exudate management than Aquacel Ag. On exposure to high levels of wound exudate, Silvercel retained its shape and mechanical strength, and remained at the site of application. In contrast, Aquacel Ag formed a fluid (semi-fibrous) gel, with minimal mechanical integrity and variable retention at the wound site. Silvercel was significantly more adherent to wound tissues than Aquacel Ag, but the level of trapped dressing debris, the frequency of ensuing foreign body reactions and the level of consequent wound-tissue disruption was lower, although not statistically, in the Silvercel-treated wounds.ConclusionThese results suggest that the potential adverse clinical consequences of unmanaged wound exudate may be less likely in Silvercel than Aquacel Ag-treated wounds. In addition, the adverse effects of dressing adherence may be less likely in Aquacel Ag-treated wounds, although such benefits may be negated by the potentially deleterious effects of elevated dressing debris deposition. In view of these findings, further development of absorbent fibre-based dressings should be directed at maximising exudate management, minimising dressing adherence and preventing dressing-debris entrapment.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.