• Neurogastroenterol. Motil. · Feb 2015

    Inter- and intrarater reliability of the Chicago Classification in pediatric high-resolution esophageal manometry recordings.

    • M M J Singendonk, M J Smits, I E Heijting, M P van Wijk, S Nurko, R Rosen, P W Weijenborg, R Abu-Assi, D R Hoekman, S Kuizenga-Wessel, G Seiboth, M A Benninga, T I Omari, and S Kritas.
    • Department of Pediatric Gastroenterology and Nutrition, Emma Children's Hospital AMC, Amsterdam, The Netherlands; Gastroenterology Unit, Women's and Children's Health Network, North Adelaide, SA, Australia.
    • Neurogastroenterol. Motil. 2015 Feb 1;27(2):269-76.

    BackgroundThe Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort.MethodsThirty pediatric solid state HRM recordings (13M; mean age 12.1 ± 5.1 years) assessing 10 liquid swallows per patient were analyzed twice by 11 raters (six experts, five non-experts). Software-placed anatomical landmarks required manual adjustment or removal. Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), contractile front velocity (CFV), distal latency (DL) and break size (BS), and an overall CC diagnosis were software-generated. In addition, raters provided their subjective CC diagnosis. Reliability was calculated with Cohen's and Fleiss' kappa (κ) and intraclass correlation coefficient (ICC).Key ResultsIntra- and interrater reliability of software-generated CC diagnosis after manual adjustment of landmarks was substantial (mean κ = 0.69 and 0.77 respectively) and moderate-substantial for subjective CC diagnosis (mean κ = 0.70 and 0.58 respectively). Reliability of both software-generated and subjective diagnosis of normal motility was high (κ = 0.81 and κ = 0.79). Intra- and interrater reliability were excellent for IRP4s, DCI, and BS. Experts had higher interrater reliability than non-experts for DL (ICC = 0.65 vs ICC = 0.36 respectively) and the software-generated diagnosis diffuse esophageal spasm (DES, κ = 0.64 vs κ = 0.30). Among experts, the reliability for the subjective diagnosis of achalasia and esophageal gastric junction outflow obstruction was moderate-substantial (κ = 0.45-0.82).Conclusions & InferencesInter- and intrarater reliability of software-based CC diagnosis of pediatric HRM recordings was high overall. However, experience was a factor influencing the diagnosis of some motility disorders, particularly DES and achalasia.© 2014 John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…