Neurosurgical review · Jan 2013
Case ReportsEndoscope-integrated ICG technology: first application during intracranial aneurysm surgery.
- Michaël Bruneau, Geoffrey Appelboom, Michal Rynkowski, Nathalie Van Cutsem, Benjamin Mine, and Olivier De Witte.
- Department of Neurosurgery, Erasme Hospital, Université Libre de Bruxelles-ULB, Route de Lennik, 808, 1070, Brussels, Belgium. mbruneau@ulb.ac.be
- Neurosurg Rev. 2013 Jan 1;36(1):77-84; discussion 84-5.
AbstractMicroscopic indocyanine green videoangiography (mICG-VA) has gained wide acceptance during intracranial aneurysm surgery by lowering rates of incomplete clipping and occlusion of surrounding vessels. However, mICG-VA images are limited to the microscopic view and some deeper areas, including the aneurysm sac/neck posterior side, cannot be efficiently assessed as they are hidden by the aneurysm, clips, or surrounding structures. Contrarily, endoscopes allow a wider area of visualization, but neurosurgical endoscopes to date only provided visual data. We describe the first application of endoscope ICG-integrated technology (eICG) applied in an initial case of anterior communicating artery aneurysm clipping. This new technique provided also relevant information regarding aneurysm occlusion and patency of parent and branching vessels and small perforating arteries. eICG-VA provided additional information compared to mICG-VA by magnifying areas of interest and improving the ability to view less accessible regions, especially posterior to the aneurysm clip. Obtaining eICG sequences required currently the microscope to be moved away from the operating field. eICG-VA was only recorded under infrared illumination which prevented tissue handling, but white-infrared light views could be interchanged instantaneously. Further development of angled endoscopes integrating the ICG technology and dedicated filters blocking the microscopic light could improve visualization capacities even further. In conclusion, as a result of its ability to reveal structures around corners, the eICG-VA technology could be beneficial when used in combination with mICG-VA to visualize and confirm vessel patency in areas that were previously hidden from the microscope.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.