    Stabilizing potential of anterior, posterior, and circumferential fixation for multilevel cervical arthrodesis: an in vitro human cadaveric study of the operative and adjacent segment kinematics.

    • Anton E Dmitriev, Timothy R Kuklo, Ronald A Lehman, and Michael K Rosner.
    • Spine Research Laboratory and Department of Orthopaedics and Rehabilitation, Walter Reed Army Medical Center, Washington, DC 20012, USA. AEDortho@gmail.com
    • Spine. 2007 Mar 15;32(6):E188-96.

    Study DesignThis is an in vitro biomechanical study.ObjectiveThe current investigation was performed to evaluate the stabilizing potential of anterior, posterior, and circumferential cervical fixation on operative and adjacent segment motion following 2 and 3-level reconstructions.Summary Of Background DataPrevious studies reported increases in adjacent level range of motion (ROM) and intradiscal pressure following single-level cervical arthrodesis; however, no studies have compared adjacent level effects following multilevel anterior versus posterior reconstructions.Materials And MethodsTen human cadaveric cervical spines were biomechanically tested using an unconstrained spine simulator under axial rotation, flexion-extension, and lateral bending loading. After intact analysis, all specimens were sequentially instrumented from C3 to C5 with: (1) lateral mass fixation, (2) anterior cervical plate with interbody cages, and (3) combined anterior and posterior fixation. Following biomechanical analysis of 2-level constructs, fixation was extended to C6 and testing repeated. Full ROM was monitored at the operative and adjacent levels, and data normalized to the intact (100%).ResultsAll reconstructive methods reduced operative level ROM relative to intact specimens under all loading methods (P < 0.05). However, circumferential fixation provided the greatest segmental stability among 2 and 3-level constructs (P < 0.05). Moreover, anterior cervical plate fixation was least efficient at stabilizing operative segments following C3-C6 arthrodesis (P < 0.05). Supradjacent ROM was increased for all treatment groups compared to normal data during flexion-extension testing (P < 0.05). Similar trends were observed under axial rotation and lateral bending loading. At the distal level, flexion-extension and axial rotation testing revealed comparable intergroup differences (P < 0.05), while lateral bending loading indicated greater ROM following 2-level circumferential fixation (P < 0.05).ConclusionsResults from our study revealed greater adjacent level motion following all 3 fixation types. No consistent significant intergroup differences in neighboring segment kinematics were detected among reconstructions. Circumferential fixation provided the greatest level of segmental stability without additional significant increase in adjacent level ROM.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…