    A novel noninvasive measurement technique for analyzing the pressure pulse waveform of the radial artery.

    • Chu-Chang Tyan, Shing-Hong Liu, Jan-Yow Chen, Jian-Jung Chen, and Wen-Miin Liang.
    • Graduate Institute of Chinese Medical Science, China Medical University (CMU), China Medical University Hospital (CMUH), Taichung, Taiwan.
    • IEEE Trans Biomed Eng. 2008 Jan 1;55(1):288-97.

    AbstractPrevious noninvasive measurements of the pulse waveform of the radial artery have not employed standard positioning procedures. Here, we propose a new noninvasive measuring apparatus that has a two-axis mechanism and employs a standard positioning procedure for detecting the optimal site for accurately measuring the pressure pulse waveform (PPW). A modified sensor was designed to simultaneously measure the arterial diameter changed waveform (ADCW) and PPW. Considering the artery as a cylinder, the measured waveform would be distorted if the sensor were not at the middle of arterial width. Moreover, a blood vessel is elastic, and its compliance changes with the transmural pressure, being maximal when the transmural pressure is equal to zero. The sensor should detect the PPW with the lowest possible distortion and, hence, an analysis of the vascular geometry and an arterial model were used to design a standard positioning procedure based on the ADCW for the X and Z axes. In order to verify the resolution of the X axis scanning procedure, the echo method was used to measure the radial artery outer diameter in ten healthy subjects. The difference between the scanning width and the actual arterial diameter was 0.36 +/- 0.23 mm (mean +/- SD). Finally, the PPW as measured at the optimal position was used to diagnose myocardial ischemia symptoms in 60 elderly subjects whose chief complaint was chest pain, with the exercise electrocardiogram being used as a reference to compare between individuals with and without myocardial ischemia. The PPW analysis used the harmonic components in the frequency domain. We found that the fourth harmonic of the Fourier series differed significantly between the groups (p = 0.0039), which is consistent with previous studies. The results indicate that our noninvasive measurement apparatus is very suitable for analyzing the PPW of the radial artery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.