-
Emergency (Tehran, Iran) · Jan 2015
Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure.
- Keihan Golshani, Mehdi Ebrahim Zadeh, Ziba Farajzadegan, and Fariborz Khorvash.
- Department of Emergency Medicine, Alzahra Hospital, Isfahan University of Medical Sciences, Isfahan, Iran.
- Emerg (Tehran). 2015 Jan 1;3(2):54-8.
IntroductionElevated intracranial pressure (ICP) is a major and potentially lethal disorder in patients admitted to the emergency department (ED). Several methods are being used to investigate for elevated ICP. Here we assessed and compared the diagnostic accuracy of two existing tools of ophthalmoscopy and optic nerve ultrasonography in detection of elevated ICP.Methods131 participants with probable elevation of ICP referred to the emergency department of Al-Zahra Hospital, Isfahan, Iran, from 2012 to 2014, were enrolled. Brain computed tomography (CT) scan, ultrasonography of optic nerve sheath, and ophthalmoscopy were performed for them. The optic nerves sheath with diameter more than 5 millimeters was considered as elevated ICP. Widening of optic nerve, ocular venous engorgement, blurring, hemorrhage over optic disk, elevation of optic disk, and retinal venous tortuosity were recorded as evidences of ICP rising in ophthalmoscopy. Diagnostic accuracy of the two tools in prediction of ICP rising were compared with the results of brain CT scan as a gold standard.ResultsThe mean age of participants was 46.29 ± 10 years (77% male). The number of diagnosed elevated ICPs with ophthalmoscopy and ultrasound were 98 (74.8%) and 102 (77.9%) cases, respectively. The calculated sensitivity and specificity of ophthalmoscopy and ultrasonography in detection of ICP rising were 100.0% (95% CI: 88.6-100.0) and 35.4% (95% CI: 26.0-46.2), 100.0% (95% CI: 84.0-100.0) and 31.9% (95% CI: 23.0-41.7), respectively.ConclusionThe present study revealed that bedside ultrasonography of optic nerve sheath and ophthalmoscopy have enough accuracy for the screening of patients with probable elevation of ICP. Of course, it should be considered that despite the high sensitivity of both tools, their specificity is low.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.