-
J. Cardiothorac. Vasc. Anesth. · Dec 2014
Inaccuracy of the FloTrac/Vigileo™ System in Patients With Low Cardiac Index.
- Takuma Maeda, Kenji Yoshitani, Yuzuru Inatomi, and Yoshihiko Ohnishi.
- Department of Anesthesiology, National Cerebral and Cardiovascular Center, Osaka, Japan. Electronic address: takuma@ncvc.go.jp.
- J. Cardiothorac. Vasc. Anesth.. 2014 Dec 1;28(6):1521-6.
ObjectivesThe goal of this study was to compare cardiac output derived from the FloTrac/Vigileo™ system (CO(FT)) with cardiac output measured by 3-dimensional transesophageal echocardiography (CO3D) in patients with severe heart failure undergoing cardiac resynchronization therapy. The impact of preoperative systemic vascular resistance index on the accuracy of the FloTrac/Vigileo™ system also was investigated.DesignProspective clinical study.SettingCardiac surgery operating room of a single cardiovascular center.ParticipantsForty-one patients undergoing elective cardiac resynchronization therapy lead implantation.InterventionsCO3D as the reference method and CO(FT) were determined simultaneously after induction of anesthesia.Measurements And Main ResultsLinear regression analysis showed a poor correlation between CO3D and CO(FT) (R² = 0.16). Bland-Altman plots showed wide limits of agreement between CO3D and CO(FT.). Bias was 0.60 ± 0.63 L/min with a high percentage error of 58.2%. Subgroup analysis showed that the percentage error between CO3D and CO(FT) was 74.1% in patients with a cardiac index<2.2 L/min/m(2) and 17.2% in patients with a cardiac index ≥ 2.2 L/min/m(2). Systemic vascular resistance index was significantly higher in patients with a cardiac index<2.2 L/min/m(2) (3,037 ± 820 v 2,461 ± 878; p = 0.039).ConclusionsThe FloTrac/Vigileo™ system is not accurate in patients with low cardiac output, especially those with a cardiac index<2.2 L/min/m(2). A high systemic vascular resistance index in patients with low cardiac index may contribute to this inaccuracy.Copyright © 2014 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.