Anesthesia and analgesia · Jan 2004
Randomized Controlled Trial Clinical TrialAdministration of 100% oxygen before removal of the laryngeal mask airway does not affect postanesthetic arterial partial pressure of oxygen.
- Markus Renner, Matthias Hohlrieder, Thomas Wölk, Friedrich Pühringer, Axel T Kleinsasser, Christian Keller, and Arnulf Benzer.
- Department of Anesthesiology and Critical Care Medicine, Klinikum am Steinenberg, Reutlingen, Germany.
- Anesth. Analg. 2004 Jan 1;98(1):257-9, table of contents.
UnlabelledBreathing 100% oxygen at the end of general anesthesia has been shown to worsen postoperative pulmonary gas exchange when an endotracheal tube is used. Counter measures, such as high positive end-expiratory pressure or the vital-capacity maneuver, may limit this effect. Such strategies, however, may be impracticable, or even contraindicated, when the laryngeal mask airway (LMA) is used. Because of the vast differences in design between the LMA and endotracheal tube, we examined postanesthetic blood gas tensions in patients after emergence from anesthesia breathing oxygen via LMA. Sixty-four ASA physical status I-II patients undergoing general anesthesia for 60 min with LMA were randomly assigned to receive either 100% or 30% oxygen during emergence from anesthesia and removal of LMA. Postoperative blood gas measurements were taken at 30 and 60 min after removal of the LMA. At either measurement, patients treated with 100% oxygen essentially had the same arterial partial pressure of oxygen (60-min measurement: 83 +/- 8 versus 85 +/- 7 mm Hg [mean +/- SD], P = 0.14) as those treated with 30% oxygen. We conclude that breathing 100% oxygen at the end of general anesthesia does not worsen postoperative pulmonary gas exchange when an LMA is used.ImplicationsThe endotracheal tube and laryngeal mask airway are substantially different artificial airways used to ventilate the lungs of anesthetized patients. Breathing 100% oxygen before removing the endotracheal tube results in lung function defects. This study shows that oxygen breathing before removing the laryngeal mask airway has no effect on pulmonary function.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.