• J Invasive Cardiol · Jun 2014

    Transthoracic echocardiography as a measuring and guiding tool for transcatheter device closure of secundum atrial septal defect in young children.

    • Nadeem Sadiq, Maad Ullah, Mehboob Sultan, and Khurram Akhtar.
    • Pediatric Cardiology Department, Armed Forces Institute of Cardiology & National Institute of Heart Diseases (AFIC/ NIHD) Rawalpindi, Pakistan. drnadeemsadiq@yahoo.com.
    • J Invasive Cardiol. 2014 Jun 1;26(6):245-8.

    ObjectiveTo analyze the effectiveness of transthoracic echocardiography (TTE) for device closure of secundum atrial septal defect in children ≤5 years old.Study DesignQuasiexperimental study.Study Location And DurationThe study was conducted at Armed Forces Institute of Cardiology and National Institute of Heart Diseases from December 1, 2010 to December 31, 2012.Patients And MethodsDuring the study period, a total of 48 children ≤5 years old underwent device closure of secundum atrial septal defect. The indications for closure were: elective closure in 31; parental anxiety in 10; frequent respiratory infection in 4; severe pulmonary stenosis in 2; and severe mitral stenosis in 1 patient. The procedure was carried out under general or local anesthesia with TTE and fluoroscopic guidance. TTE was the primary tool used for measurement of defect and estimation of occluder size as well as guiding equipment during device deployment in all patients.ResultsA total of 47/48 patients (97.9%) had successful closure of secundum atrial septal defect. The mean age was 4.1 ± .68 years (range, 2.5-5 years) and 28/48 patients (58.4%) were female. The defect size and occluders used were between 5-20 mm (mean, 12 ± 3.5 mm) and 8-22 mm (mean, 15 ± 3.9 mm), respectively. Three patients had simultaneous procedures comprising pulmonary balloon valvuloplasty in 2 patients and percutaneous transmitral commissurotomy in 1 patient. The device embolization occurred in 1 patient; the device was retrieved percutaneously and the patient was referred for surgical closure. The minor complications were residual leak (n = 1), transient bradycardia (n = 4), and first-degree heart block (n = 1). The median procedure time was 30 min (range, 15-100 min) and median fluoroscopic time was 6 min (range, 1.50-45 min). There were no emergency surgical explorations, cardiac perforations, vascular injuries, or deaths during this period.ConclusionTTE can be used as a primary tool for the measurement of atrial septal defect and guidance during device deployment in young children by skilled and professional hands, yet more experience is awaited.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…