-
J Clin Monit Comput · Oct 2015
Comparative StudyNoninvasive assessment of peripheral microcirculation by near-infrared spectroscopy: a comparative study in healthy smoking and nonsmoking volunteers.
- Guillaume Zamparini, Géraldine Butin, Marc-Olivier Fischer, Jean-Louis Gérard, Jean-Luc Hanouz, and Jean-Luc Fellahi.
- Department of Anesthesiology and Critical Care Medicine, Pôle Réanimations Anesthésie SAMU, CHU de Caen, Avenue de la Côte de Nacre, 14000, Caen, France. zamparini-g@chu-caen.fr.
- J Clin Monit Comput. 2015 Oct 1; 29 (5): 555-9.
AbstractSmokers are exposed to early endothelial dysfunction. This microcirculatory damage can be demonstrated by near-infrared spectroscopy (NIRS). The aim of this study was to compare microvascular reactivity by NIRS during a dynamic vascular occlusion test in healthy smokers and nonsmokers volunteers. Twenty healthy volunteers (10 men, 10 women), aged from 22 to 38 years old, were included after approval of the local Ethics Committee and divided into two groups: smokers (n = 10) and nonsmokers (n = 10). Tissue oxygen saturation (StO2) was measured at the level of each individual's calves during an ischemia and reperfusion test. In addition, during the ischemia phase, the slope of decline in StO2 was determined. Therefore, for each group, we were able to deduce the speed of desaturation (ΔStO2/ischemia time). The same was applied for resaturation rates during the reperfusion phase (ΔStO2/reperfusion time). StO2 values were comparable at all experimental steps between smokers and nonsmokers. During the vascular occlusion test, rates of desaturation were the same between smokers and nonsmokers [respectively 3.7%·min(-1) (range 2.5-12.6) and 3.7%·min(-1) (range 1.8-15.1); p = 0.50]. It was the same for the rate of resaturation [smokers 30.4%·min(-1) (range 14.2-51.6) and nonsmokers 30.5%·min(-1) (range 18.6-44.5); p = 0.82]. NIRS study of microvascular reactivity during a dynamic vascular occlusion test did not reveal any difference between smokers and nonsmokers. Therefore, NIRS could not be sensitive enough to highlight endothelial dysfunction in healthy subjects exposed to tobacco smoke.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.