• Emerg Med Australas · Dec 2014

    Peripheral intravenous catheter duration and failure in paediatric acute care: A prospective cohort study.

    • Lorelle Malyon, Amanda J Ullman, Natalie Phillips, Jeanine Young, Tricia Kleidon, Jenny Murfield, and Claire M Rickard.
    • Department of Emergency Medicine, Royal Children's Hospital, Brisbane, Queensland, Australia; School of Nursing, Midwifery and Paramedicine, Australian Catholic University, Brisbane, Queensland, Australia; Children's Medical Research Institute, The University of Queensland, Brisbane, Queensland, Australia.
    • Emerg Med Australas. 2014 Dec 1;26(6):602-8.

    ObjectiveChildren admitted to hospital commonly require peripheral intravenous catheters (PIVCs) for treatment. This study sought to address a gap in the literature about current practice in the securement and dressing of PIVCs in paediatric acute care, and to ascertain the duration and failure of these devices.MethodsA prospective cohort study conducted at the Royal Children's Hospital in Queensland, Australia. All patients aged 0-15 years, who presented to the ED between 16 July and 16 October 2012, and had a PIVC inserted prior to emergent admission to the hospital were included.ResultsOf 458 participants, median device duration was 29 h (IQR 13-58 h), and ranged from less than 1 h to 16 days. One quarter (113/456, 24.8%) of PIVCs were removed due to device failure, presenting as: infiltration (65/456, 14.3%); accidental dislodgement (23/456, 5.0%); blockage (12/456, 2.6%); phlebitis (7/456, 1.5%); or 'other' (6/456, 1.3%). PIVC securement and dressings were predominantly bordered polyurethane dressings and splints (n = 457/458, 99.8%). PIVC placement in the antecubital fossa, in comparison to the hand, was significantly associated with an increased risk for failure (P = 0.03). No other patient and device characteristics had a significant association with device failure (P > 0.05). The median dwell time of PIVCs that failed was significantly longer than the PIVCs that did not fail (44.0 vs 25.5 h; P = 0.002). Less than half (53/113, 46.9%) of failed catheters were replaced with a new PIVC.ConclusionsObserved failure rates were high for a clinically essential device; however, there is no established rate of acceptability against which the results can be benchmarked against to facilitate effectiveness of practice. Many PIVCs appeared to remain in place longer than needed. Dressing and securement practice was homogenous. PIVC placement in the antecubital fossa should be minimised to reduce the risk of paediatric PIVC failure.© 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.