-
- Bryan W Cunningham.
- Orthopaedic Biomechanics Laboratory, Union Memorial Hospital, 201 East University Parkway, Baltimore, MD 21218, USA. bcspine@aol.com
- Spine J. 2004 Nov 1;4(6 Suppl):219S-230S.
Background ContextTotal disc arthroplasty serves as the next frontier in the surgical management of intervertebral discogenic pathology.PurposeAs we move from an era of interbody spinal arthrodesis to one in which segmental motion is preserved, this promising new technology offers increasing clinical and research challenges in the areas of spinal kinematics, histologic osseointegration at the prosthetic-bone interface and the effects of particulate wear debris.Study DesignThe primary focus of this paper is to provide a methodologic basis to investigate the spinal kinematics, histologic osseointegration and particulate wear debris after total disc arthroplasty by using in vitro and in vivo models.MethodsPart I: Using an in vitro cadaveric model, multidirectional flexibility testing evaluated the functional unit kinematics under the following L4-L5 reconstruction conditions: 1) intact spine, 2) Charite disc prosthesis, 3) BAK cages, 4) BAK cages+ISOLA pedicle screw or rod fixation (anteroposterior). Part II: A total of 27 mature baboons (n=27, Papio cynocephalus) underwent L5-L6 total disk replacement procedures to investigate the biomechanical, histochemical and biologic ingrowth characteristics of two different lumbar disc prostheses (AcroFlex and Charite) for total disc arthroplasty. Functional spinal unit fusion status was assessed by using radiographic analysis, biomechanical testing, undecalcified histopathologic and histomorphometric analyses. Part III: Using a total of 50 New Zealand white rabbits, this investigation served to quantify the neural and systemic tissue histopathologic response, after epidural application of four different types of spinal instrumentation particulate wear debris: 1) sham (control) (n=10), 2) stainless steel 316LVM (n=10), 3) titanium alloy Ti-6AL-4V (n=10), 4) cobalt chrome alloy (n=10) and 5) ultrahigh molecular weight polyethylene (UHMWPE) (n=10).ResultsIn vitro multidirectional flexibility testing demonstrates the operative and adjacent level motion-preserving properties of total disc arthroplasty versus interbody arthrodesis cages and pedicle screw spinal instrumentation. To this end, disc replacement preserves the normal centrode or locus of intervertebral rotation at the operative and adjacent intervertebral spinal levels compared with conventional stabilization implants. On the basis of nonhuman primate modeling in the current studies, porous titanium interface surfaces afforded the greatest percentage of trabecular ingrowth at the prosthesis-end plate interface. In vivo segmental motion under multidirectional testing was preserved with the Charite device and slightly diminished with the AcroFlex implants. The porous ingrowth coverage at the bone-metal interface was more favorable for total disk replacement (range, 40% to 50%) compared with that reported for cementless total joint components in the appendicular skeleton (range, 10% to 30%). Direct epidural application of spinal instrumentation particulate wear debris elicits a chronic histiocytic reaction localized primarily within the epidural fibrous layers. Moreover, particles have the capacity to diffuse intrathecally, eliciting a macrophage and cytokine response within the epidural tissues, cerebrospinal fluid and spinal cord itself. Overall, on the basis of the postoperative time periods evaluated, no evidence was observed of an acute neural or systemic histopathologic response to the materials included in the current project.ConclusionThe implementation of dynamic spinal stabilization systems for fusionless correction of spinal deformity, dynamic posterior stabilization and total disc arthroplasty necessitates improved understanding with regard to spinal kinematics, patterns and mechanisms of histologic osseointegration and the neurohistopathologic response to particulate wear debris. Collectively, the current studies provide a methodologic basis to comprehensively evaluate these three areas.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.