• Clin. Orthop. Relat. Res. · Dec 2011

    Precontoured plating of clavicle fractures: decreased hardware-related complications?

    • Corinne VanBeek, Karen J Boselli, Edwin R Cadet, Christopher S Ahmad, and William N Levine.
    • Center for Shoulder, Elbow and Sports Medicine, Department of Orthopaedic Surgery, Columbia University Medical Center, 622 West 168th Street PH 11, New York, NY 10032, USA.
    • Clin. Orthop. Relat. Res. 2011 Dec 1;469(12):3337-43.

    BackgroundOperative treatment of displaced midshaft clavicle fractures reportedly decreases the risk of symptomatic malunion, nonunion, and residual shoulder disability. Plating these fractures, however, may trade these complications for hardware-related problems. Low-profile anatomically precontoured plates may reduce the rates of plate prominence and hardware removal.Questions/PurposesWe compared the outcomes after precontoured and noncontoured superior plating of acute displaced midshaft clavicle fractures. Primary outcomes were rate of plate prominence, rate of hardware removal, and rate of complications. Secondary outcomes were ROM and pain and function scores.Patients And MethodsWe retrospectively reviewed 52 patients with 52 acute, displaced midshaft clavicle fractures treated with either noncontoured or precontoured superior clavicle plate fixation. Fourteen patients with noncontoured plates and 28 with precontoured plates were available for followup at a minimum of 1 year postoperatively. Postoperative assessment included ROM, radiographs, and subjective scores including visual analog scale for pain, American Shoulder and Elbow Surgeons questionnaire, and Simple Shoulder Test.ResultsPatients complained of prominent hardware in nine of 14 in the noncontoured group and nine of 28 in the precontoured group. Hardware removal rates were three of 14 in the noncontoured group and three of 28 in the precontoured group. Postoperative ROM and postoperative subjective scores were similar in the two groups.ConclusionsPrecontoured plating versus noncontoured plating of displaced midshaft clavicle fractures results in a lower rate of plate prominence in patients who do not undergo hardware removal.Level Of EvidenceLevel III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…